MIB Viewer

fibTmuFunctChkRingPerPerm

OBJECT-TYPE
1.3.6.1.4.1.22.60.8.2.14
Access
read-write
Status
mandatory
Source
TMU-MIB
Sub-identifiers
0
Parameter indicating the elapsed time after letting a station into the ring after which a station is considered to be o.k. See 'fibTmuFunctChkRingInsPerm' Units: milli seconds. Minimal value: 1500. maximal value 4000. Factory default: 3000 Setting this variable loads it into non volatile memory. The value written into non volatile memory is loaded into the current value only after reset.
INTEGER (1500..4000)