MIB Viewer

svrLogicalDriveStatusEx

OBJECT-TYPE
1.3.6.1.4.1.231.2.49.1.6.2.1.19
Access
read-only
Status
mandatory
Sub-identifiers
0
Status of the logical drive: operational(2): drive is OK, all disks working properly partiallyDegraded(3): one disk in this array failed, reduced redundancy still available degraded(4): one disk in this array failed, redundancy lost failed(5): too many disks in this array failed, drive no longer available rebuilding(6): drive is currently rebuilding checking(7): drive is currently executing a consistency check mdcing(8): drive is currently executing a consistency check and fixes inconsistencies initializing(9): drive is currently being initialized backgroundInitializing(10): drive is currently being initialized in background migrating(11): drive is currently being modified (online RAID extension) copying(12): drive is currently executing a copyback or redundant copy operation offline(13): drive is temporarily not operational spareInUse(14): drive is using a hot spare erasing(15): drive is being erased
INTEGER { unknown(1), operational(2), partiallyDegraded(3), degraded(4), failed(5), rebuilding(6), checking(7), mdcing(8), initializing(9), backgroundInitializing(10), migrating(11), copying(12), offline(13), spareInUse(14), erasing(15) }