MIB Viewer

psAlarmMeasurementEngineStatus

OBJECT-TYPE
1.3.6.1.4.1.2334.2.1.5.18
Access
read-only
Status
mandatory
Sub-identifiers
0
The current status of the Measurement Engine. The values enumerated above correspond to those shown in the command line 'me show' command. (1) initially starting (2) starting (3) running (4) error on volume (5) disabled (6) wait to start (7) suspended (8) backing up data (9) restoring data
INTEGER { initiallyStarting(1), starting(2), running(3), errorOnVolume(4), disabled(5), waitToStart(6), suspended(7), backup(8), restore(9) }