MIB Viewer

aviciBayVoltageNotification

NOTIFICATION-TYPE
1.3.6.1.4.1.2474.1.4.2.0.1
Status
current
Sub-identifiers
0
A Voltage notification is sent when a change is detected in the 5 volt backplane communication rails. These backplane communication rails are used by the bay controller to communicate with the occupant of a given slot. There are 8 rails, each servicing the slots in one half of a shelf in the bay (aviciBayVoltageIndex == rail): Rail Slots ============== 1 1 - 5 2 6 - 10 3 11 - 15 4 16 - 20 5 21 - 25 6 26 - 30 7 31 - 35 8 36 - 40 If the voltage is out of specification, the communication path will not function. When a given backplane communication channel is not functioning, modules serviced by this rail cannot be discovered (if a module is inserted) and will not be authorized to boot (if an existing module reboots). The current voltage is reported in the aviciBayVoltage object. A human readable description of the event triggering this notification is included in the aviciSysTrapDescr object.