MIB Viewer

riLdcSlotDiagnostic

OBJECT-TYPE
1.3.6.1.4.1.28.10.10.1.10
Access
read-only
Status
mandatory
Sub-identifiers
0
The results of the internal startup (i.e., nondestructive) diagnostics for the logic and connectivity modules in a slot. This variable returns either pass(92) or fail(93), indicating the general results of the diagnostic tests. If the variable returns fail(93), see the next variable, Slot Diagnostic Code, for information about which test failed.
INTEGER { pass(92), fail(93), other(200) }