MIB Viewer

riLdcHfExtPing2

OBJECT-TYPE
1.3.6.1.4.1.28.10.14.14
Access
read-write
Status
mandatory
Sub-identifiers
0
The IP address of a second node to ping should the first host not respond (see the previous variable, Ext Failover Detection/Ping 1). This eliminates the false hot failover detections that occur when the ping1 host is rebooting at the time the ping is made. The INX-NMM only tries to ping this address once the ping address reverts to the one specified by Ext Failover Detection/Ping 1. As with Ext Failover Detection/Ping1, set this variable to the address of the node to which the master INX-NMM will ping to detect external cable failures. The master INX-NMM sends the pings on the bus for which its NIC is configured (i.e., the value of Logic Module Bus). If you set this variable to 0.0.0.0, external hot failover detection is enabled, but only Ext Failover Detection/Ping1 is used.
IpAddress