MIB Viewer

statusCurrentTemperatureConditionState

OBJECT-TYPE
1.3.6.1.4.1.285.2.6.3.1.6
Access
read-only
Status
mandatory
Sub-identifiers
0
The current state of the temperature within the switch. Possible values are: normal The temperature is below fhTrapDashboardControlThresholdLow. highDecreasing The temperature is between fhTrapDashboardControlThresholdLow and fhTrapDashboardControlThresholdHigh, and it is decreasing. normalIncreasing The temperature is between fhTrapDashboardControlThresholdLow and fhTrapDashboardControlThresholdHigh, and it is increasing. high The temperature is above fhTrapDashboardControlThresholdHigh. The references to fhTrapDashboardControlThresholdLow/High refer to the temperatureWarning entry in fhTrapDashboardControlTable.
INTEGER { normal(1), highDecreasing(2), normalIncreasing(3), high(4) }