MIB Viewer

sonusStShelfAdmnSourceReconfigAlg

OBJECT-TYPE
1.3.6.1.4.1.2879.2.1.3.1.1.1.11
Access
read-write
Status
current
Sub-identifiers
0
This object indicates which algorithm should be used to select timing sources for use as System Synchronized sources. Selecting Ordered_list causes sources to be selected for use in strict numerical order, as assigned by default or by the operator. Selecting SSM_Quality will cause sources to be selected based upon the quality level of the timing source, as indicated by the sources Synchronized Status Messages. Do not select SSM_Quality unless all configured timing sources support SSM's
INTEGER { ordered-list(1), ssm-quality(2) }