MIB Viewer

ansProfConnProfRequired

OBJECT-TYPE
1.3.6.1.4.1.304.1.3.1.12.7
Access
read-write
Status
mandatory
Sub-identifiers
0
Indicates whether or not an incoming call must match a connection profile entry in the connProfileTable. If the value of this object is 'connProfRequired(1)', incoming calls not matching a connection profile entry in the connProfileTable will be rejected. If the value of this object is 'connProfNotRequired(2)', then incoming calls not matching a connection profile entry in the connProfileTable will be accepted, and will be governed by a temporary connection profile created from the values of the following objects: ansProfIsdnBandwidth ansProfRxRip ansProfTxRip ansProfFilterSetIndex ansProfIdleSeconds ansProfPppMaxRecvUnit ansProfPppLinkCompression ansProfIsdnInForce56K If the value of this object is 'connProfNotRequired(2)', the actual value of the ansProfPppRecvAuthProt object is ignored, and the device behaves as if the value of that object is 'authNone(1)'.
INTEGER { connProfRequired(1), connProfNotRequired(2) }