MIB Viewer

csOrionSystemTime

OBJECT-TYPE
1.3.6.1.4.1.3085.3.1.2.1.9
Access
read-write
Status
current
Sub-identifiers
0
To set the system date & time with the standard format specified by RFC 2579. Below is the date-time specification. (Display Format: YYYY-MM-DD,HH:MM:SS.ss,+/-:HH:MM) field contents range 1 year* 1999..2098 2 month 1..12 3 day 1..31 4 hour 0..23 5 minutes 0..59 6 seconds 0..60 (use 60 for leap-second) 7 deci-seconds 0..9 8 direction from UTC '+' / '-' 9 hours from UTC* 0..13 10 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 2000 at 1:30:15 PM EDT would be displayed as: 2000-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present.