MIB Viewer

mbAlarmInterval

OBJECT-TYPE
1.3.6.1.4.1.33.31.2.1.2
Access
read-write
Status
mandatory
Sub-identifiers
0
The interval in seconds over which the variable is sampled and compared with the rising and falling thresholds. If the monitored variable exceeds the limit 2^31-1 (4294967295), the alarm value field may roll over to 0 and cause or suppress the generation of an alarm event during that interval. You may not modify this field once the alarm is completed (see alarm status field).