MIB Viewer

mbAlarmDescription

OBJECT-TYPE
1.3.6.1.4.1.33.31.2.2.1.2
Access
read-only
Status
mandatory
Sub-identifiers
0
An easily-readable summary of an RMON alarm. The general format is: '<action> when <condition> <variable> <key2tag> <key1tag> is >= <r> or <= <f> <interval>.' <action> is from: 'Do nothing', 'Create log record', 'Generate trap', 'Create log and trap', or 'Various actions', based on the alarm rising and falling event types. <condition> is one of 'value of' or 'change in', according to the alarm sample type. <variable>, if recognized, describes the quick list selection. If unlisted, the object identifier is substituted. <key1tag> and <key2tag> appear only if <variable> is recognized and represent phrases like 'slot', 'port', and 'any port'. <r> and <f> represent the rising and falling threshold values, respectively. The <interval> phrase describes the units per N seconds or the length of the sample interval in seconds.
DisplayString (SIZE (0..255))