MIB Viewer

voiceFaxChPhyParaCfgSignallingType

OBJECT-TYPE
1.3.6.1.4.1.335.1.2.1.3.4.3.1.1.7
Access
read-write
Status
mandatory
Sub-identifiers
0
Configures where the ring signal is generated (locally or by remote PBX equipment) and the ring cadence (timing of rings and silence periods). This parameter is ONLY configurable for E&M, Enhanced and Standard E&M, 3-Port Fax, and Enhanced and Standard FXS voice modules. The following is a matrix of valid signaling type options for each configurable voice module, given the Channel Version value (voiceFaxChPhyParaChannelVersion) and Integration Unit software release (sysSoftwarePhase). Voice Module Configurable Options Chan Version Release E&M emDC,em2280,emPulseDc 2 ALL KTS repeated,interruptOR2by4, 2 ALL interrupt1by2 Std/Enh E&M emDC,em2280,emPulseDC 2,3,5 ALL emDC,em2280,emPulseDC, 6,7 Phase 5.1 emWink and Above 3-Port Fax repeated,interruptOR2by4 3,5-7 ALL Std/Enh FXS repeated,interruptOR2by4, 2,3 ALL interrupt1by2 repeated,interruptOR2by4 5-7 Phase 5.0 and Above
INTEGER { emDc (1), em2280Tone (2), emWink (3), emPulsedDc (4), repeated (5), interruptOR2by4 (6), interrupt1by2 (7) }