MIB Viewer

t1CfgDSX1LineCode

OBJECT-TYPE
1.3.6.1.4.1.335.1.2.1.3.6.1.3.2
Access
read-write
Status
mandatory
Sub-identifiers
0
Configures the line coding method (at the Local interface) either to Alternate Mark Inversion (AMI) coding or Bipolar Eight Zero Suppression (B8ZS). In AMI 0's are indicated by the absence of a pulse, and 1's are indicated by either a positive or negative polarity pulse. In B8ZS an all 0 byte is replaced by a special code of 00011011 which indicate two fixed bipolar code violations. On remote end these violations are ignored and the data is retrieved.
INTEGER { ami (1), b8zs (2) }