MIB Viewer

frLportPolVerTmr

OBJECT-TYPE
1.3.6.1.4.1.351.100.4.2.1.1.1.20
Access
read-write
Status
mandatory
Sub-identifiers
0
The link integrity verification timer heartbeat (keep-alive) period. It should be set to 5 seconds more than the heartbeat time in the user device. Default is 15 seconds. - Get Operation: Since this object is not applicable to disabled protocol, SNMP-OBJ-NA (-1) is returned if the network manager attempts to GET this object from a port without protocols. - Set Operation: If the network manager attempts to SET this object of a port without any protocol, an error is reported.
INTEGER (5..30)