MIB Viewer

slotCardStatus

OBJECT-TYPE
1.3.6.1.4.1.36.2.15.3.3.3.1.4.3.1.2
Access
read-write
Status
mandatory
Sub-identifiers
0
The status of the card. If the value is read as notPresent(1), then the entire entry should be considered invalid. Writing a value of powerDown(2) will cause the SCP to power down the card. Writing a value of powerUp(3) will cause the SCP to power up the card. Writing a value of powerDownThenUp(4) will cause the SCP to power cycle the line card. Attempts to set any other values will result in a badValue error. The clock and crossbar cards cannot be powered up or down through this object. They are fundamental to the GIGAswitch's operation. Unpopulated slots are notPresent(1), and can not be powered up or down.
INTEGER { notPresent(1), powerDown(2), powerUp(3), powerDownThenUp(4), fault(5), revisionMismatch(6), selfTestInProgress(7) }