decAtmTemperatureWarning

OBJECT-TYPE
1.3.6.1.4.1.36.2.18.30.1.9.2
Access
read-write
Status
mandatory
Sub-identifiers
0
The value of this variable determines how the switch will respond to a condition of too high or too low cabinet temperature, or a condition of all fans being inoperative. If the value is 'heedWarning(1)', the system will be shut down when the temperature goes outside the designed limits or when too many of its fans become inoperative. If the value is 'ignoreWarning(2)', the system will continue to operate when either of these conditions occur. Setting this variable to 'ignoreWarning(2)' lets a manager cause a system that is too hot or too cold to continue to run. This setting will also allow the system to run while no fans are operative. Managers should note that this may be detrimental to the equipment. This object has a default value of 'heedWarning(1)'. Note that some switches may lack auto-shutdown capability; they will have a value of 'noWarningFeature(3) for this object.
INTEGER { heedWarning(1), ignoreWarning(2), noWarningFeature(3) }