MIB Viewer

zxAnLctAccessEntry

OBJECT-TYPE
1.3.6.1.4.1.3902.1015.1.1.150.2.1.1.1
Access
not-accessible
Status
current
Sub-identifiers
5
zxAnLctAccessEntry,A list of the LCT accessing the NE information. There are two variables is mandatory when creat the entry. All of the mandatory variables must be included in one SNMP set operation.and must comply with the multi-variables binding rule. The multi-variables binding rule should be complied with when a manager creates an entry. According to this rule, all the related mib variables must be included in one SNMP set operation. There are two cases based on the variable zxAnLctAccessRowStatus. The mandatory and optional variables are different in each case. Case 1: to create an entry when LCT user login: mandatory: zxAnLctAccessDetailInfo, zxAnLctAccessRowStatus, optional : none Case 2: to destroy the session when LCT user logout: mandatory: zxAnLctAccessRowStatus, optional : none After an entry is created, no variable can be modified. If a manager tries to modify any variables in this entry, agent will return error with SNMP error code inconsistentValue.
ZxAnLctAccessEntry