MIB Viewer

usrVHAPktThroughputMajorAlarmThresh

OBJECT-TYPE
1.3.6.1.4.1.429.4.84.10.4.2
Access
read-only
Status
current
Sub-identifiers
0
The major alarm threshold for usrVHAPktThroughputValue gauge. Value of 0 disables this threshold. IF this object is set to a non-zero value equal or less than the current value of usrVHAPktThroughputClearAlarmThresh, THEN usrVHAPktThroughputClearAlarmThresh will be automatically reduced to a valid value. This value is set indirectly by setting usrVHAPktThroughputMajorAlarmThreshPct Changing threshold values causes the alarm state to be re-evaluated. IF usrVHAPktThroughputAlarmState is 'clear' and the current gauge value is equal or greater than this threshold, and the current gauge value is less than non-zero usrVHAPktThroughputCriticalAlarmThresh, and the threshold is not zero, THEN usrVHAPktThroughputAlarmState will change to 'major'. See usrVHAPktThroughputAlarmState for TRAP generation details.
Unsigned32