MIB Viewer

pollTable

OBJECT-TYPE
1.3.6.1.4.1.43.10.20.1
Access
not-accessible
Status
mandatory
Sub-identifiers
1
This table is used to provide remote device monitoring facilities. This table allows a list of network devices to be set up and polled regularly (or only once) by a variety of protocols. The table can be configured to inform the management station(s) of devices that are not responding to polls or that have started to respond after a period of silence. The minimum effort required to do a single poll is 1. In one packet, Write the address, rate=once-only(1) and RowStatus=CreateAndGo. 2. In the next packet, read the roundTripTime. The minimum effort required to monitor a device is 1. In one packet, Write the address, rate=every-30-seconds(1) and RowStatus=CreateAndGo. 2. Wait for traps to come in.
SEQUENCE OF PollTableEntry