MIB Viewer

cdx6500padpCfgTermControl

OBJECT-TYPE
1.3.6.1.4.1.449.2.1.2.1.1.1.1.11
Access
read-write
Status
mandatory
Sub-identifiers
0
Specify options for the attached device: NONE - no option specified. PASS - require password entry to use this PAD facility. LIM - limit X.28 access to CALL and CLR commands only. CUG - check closed user group; otherwise, CUG passes transparently. LCPY - allow local copying to this PAD port. 7BIT - use 7 data bits for character processing. NADD - prevent PAD port from receiving calling address and FAC service signals. X28 - automatically return from X.28 mode to PAD mode after sending the X.28 commands. CNUI - Centralized NUI verification. CUGOA - check closed user group but allow outgoing access; otherwise, CUG passes transparently. BMSG - show the PAD Bulletin/Banner Message even if the PAD Profile #6 is configured as 1 or 5. ADDR - does not show the calling address HENNIS - supports Hanil bank terminal. FRCB - connect to a French Cartes Bancaires terminal CUGIA - check closed user group but allow incoming access; otherwise, CUG passes transparently.\r\n\ NO-NULL - If port speed is below or equal to 1200, null characters won't be appended to LF. BCUG-ON- Subscription to Bilateral Closed User Group facility enabled. BCUGOA - Subscription to Bilateral Closed User Group with Outgoing Access facility enabled. BCUG-OFF-Subscription to Bilateral Closed User Group related facilities disabled. BCUG-ON, BCUGOA and BCUG-OFF options are mutually exclusive. Any combination of above specified by summing (e.g. PASS+LIM).
DisplayString (SIZE(3..60))