MIB Viewer

cdx6500padprofPar7

OBJECT-TYPE
1.3.6.1.4.1.449.2.1.2.2.8.1.9
Access
read-only
Status
mandatory
Sub-identifiers
0
#7, selects the PAD mode of operation on receipt of a break signal from the attached terminal: 0 - do nothing 1 - send Interrupt packet 2 - send Reset packet 4 - send Indication of Break packet 5 - send Interrupt packet and Indication of Break packet 8 - escape from data transfer state 21 - discard output, send Interrupt packet, and send Indication of Break Packet
INTEGER (0..21)