MIB Viewer

dfrapCfgFrDLCIMgmtDE

OBJECT-TYPE
1.3.6.1.4.1.485.6.2.1.5.4
Access
read-write
Status
mandatory
Source
DFRAP-MIB
Sub-identifiers
0
Provides user control over the state of the Frame Relay Discard Eligibility bit of all management frames generated by the unit. Frames marked DE=1 are more likely to be dropped in a congested Frame Relay network than those that are DE=0. Heavily congested circumstances can cause both to be dropped. Additionally, frames marked DE=0 may get re-marked to DE=1 by intervening equipment. (1) DE bit cleared to 0: frame is not discard eligible (2) DE bit set to 1: frame is discard eligible
INTEGER { no-DE-bit-0 (1), yes-DE-bit-1 (2) }