MIB Viewer

mfrapCfgSnmpTrapMuting

OBJECT-TYPE
1.3.6.1.4.1.485.8.2.1.3.3
Access
read-write
Status
mandatory
Source
MFRAP-MIB
Sub-identifiers
0
Controls whether TRAPs are sent or muted. A value of 0 allows TRAPs to be sent. If not 0, the value represents the interval (minutes) at which to send the MutingActive trap. It is the only trap sent during muting. The valid range for the interval is 30 to 10080 (a week).
INTEGER (0..10080)