MIB Viewer

mfrapCfgEditConnSrcPort

OBJECT-TYPE
1.3.6.1.4.1.485.8.2.10.2.3.1.3
Access
read-write
Status
mandatory
Source
MFRAP-MIB
Sub-identifiers
0
DS0 assignment for indexed destination port. The value not-connected may not be written; to clear a connection, use the mfrapCfgEditDisconnect table element. Setting mfrapCfgEditDisconnect to disconnect will cause this element to return not-connected for a get. Currently, M-FRAP will not allow setting this value to 3. Connections defined by the mfrapCfgDteTable will be reflected in reads of this object. After making any adjustments to the connections, the mfrapCfgConnUpdateCmd must be sent. Node software does not permit connections between a port and itself.
INTEGER { port2-dandi (2), port3-dte (3), not-connected (33) }