mfrapCfgDteDsrOutput

OBJECT-TYPE
1.3.6.1.4.1.485.8.2.4.19
Access
read-write
Status
mandatory
Source
MFRAP-MIB
Sub-identifiers
0
Specifies the behavior of this control signal generated by the M-FRAP towards the DTE. inactive-always (1) - signal is permanently INACTIVE. active-always (2) - signal is permanently ACTIVE. reflect-carrier (3) - signal echoes the carrier signal status from the WAN. inactive-with-test-mode (4) - signal is ACTIVE during normal data transfer and INACTIVE during diagnostic conditions that interfere with data transfer from the DTE to the WAN. follow-RTS (5) - signal echoes the status of RTS as processed from the DTE. reflect-carrier-and-RTS (6) - signal is a logical AND between RTS processed from the DTE and the carrier signal status from the WAN. No signal from the WAN or RTS INACTIVE will cause this control signal to be asserted INACTIVE. reflect-sync-and-RTS (7) - signal is a logical AND between RTS processed from the DTE and the frame synchronization with the WAN. Red Alarm defines the threshold for declaring synchronization. reflect-LMI-and-carrier-and-RTS (8) - signal is a logical AND between RTS processed from the DTE and the carrier signal status from the WAN and LMI. If the unit is in an LMI passthrough state then LMI is considered Active. LMI Inactivity timer must be non-zero for LMI to be declared Inactive. Note that there is a separate parameter for how the unit processes RTS that is related to this function if options (4), (5), (6), or (7) is selected, see CfgDteRts.
INTEGER { signal-off (1), signal-on (2), follow-carrier (3), follow-test (4), follow-rts (5), follow-carrier-rts (6), follow-sync-rts (7), follow-lmi-carr-rts (8) }