MIB Viewer

cxMcVoxEmOpeAc15Type

OBJECT-TYPE
1.3.6.1.4.1.495.2.1.1.2.9.1.1.15
Access
read-only
Status
mandatory
Sub-identifiers
0
Displays the type of AC15 signals the operative E&M port uses to seize the line for transmission. This object is only relevant to E&M ports using the AC15 signalling type (as defined using the object cxMcVoxEmAdmSignalType of the cxMcVox Administrative Driver Group). You cannot modify this object. If you want to change the value you must modify the object cxMcVoxEmAdmAcType of the cxMcVox Administrative Driver Group. Options: normal (1) delay (2) Default Value: normal
INTEGER { normal (1), delay (2) }