MIB Viewer

cxMcVoxFxoOpeDidSignalType

OBJECT-TYPE
1.3.6.1.4.1.495.2.1.1.2.9.3.1.16
Access
read-only
Status
mandatory
Sub-identifiers
0
Displays the type of signaling on the operative FXO port. The signaling type refers to the line seizure technique. You cannot modify this object. If you want to change the value you must modify the object cxMcVoxFxoAdmDidSignalType of the cxMcVox Administrative FXO Driver Group table. Options normal (1) delay (2) wink (3) Default Value: normal (1)
INTEGER { normal (1), delay (2), wink (3) }