MIB Viewer

innovxPortStatus

OBJECT-TYPE
1.3.6.1.4.1.498.22.1.1.4.2
Access
read-only
Status
mandatory
Sub-identifiers
0
A bitwise snapshot of interface port status conditions and EIA signals, where 0 = condition not present, and 1 = condition present, as follows: Octet 1 - ETHERNET Interface Port Status bit 7 - n/u bit 6 - n/u bit 5 - n/u bit 4 - Transmit Activity bit 3 - Receive Activity bit 2 - Runt packet (<64k bytes) bit 1 - CRC Error bit 0 - Transmit Collisions Octet 2 - PPP/CONSOLE Interface Port Status bit 7 - interface mode: 0 = PPP, 1 = Console, (invalid if 'handshake in progress') bit 6 - handshake in progress = 1/handshake complete = 0 bit 5 - n/u bit 4 - n/u bit 3 - n/u bit 2 - DTR Loss bit 1 - Transmit Activity bit 0 - Receive Activity
OCTET STRING (SIZE(2))