MIB Viewer

scmNodeAlarmScan

OBJECT-TYPE
1.3.6.1.4.1.498.3.6.3.2.1.5
Access
read-write
Status
mandatory
Sub-identifiers
0
This is used to turn on and off the alarm scan feature for a particular Network Element connected off of this SCM. If the alarm scan is turned off the Network Element will not be scanned for alarms and therefore no alarms will be sent to the controller for that NE. If alarms occur when the scan is off, they will be discarded.
INTEGER { on(1), off(2) }