MIB Viewer

nms520AlarmHystTime

OBJECT-TYPE
1.3.6.1.4.1.498.8.2.2.1.4
Access
read-write
Status
mandatory
Sub-identifiers
0
The Alarm hysterysis time nms520AlarmHystTime, is used to control the amount of time a remote must wait between reporting unsolicited alarm conditions. A remote will send an unsolicited alarm response at the time of the first alarm. If second alarm occurs the remote will wait for the time specified by this object before it will send another alarm response. This time applies for both point to point and multipoint applications. The range is from 1 second to 127 seconds, with 10 seconds being the default value.
INTEGER (1..127)