MIB Viewer

sc5520AddRemoteAddress

OBJECT-TYPE
1.3.6.1.4.1.498.8.3.3.1.2
Access
read-write
Status
mandatory
Sub-identifiers
0
Add Remote address from Master tells the master (SC5520) how many remotes (nms520) units are in its network, the serial number of those remote units and its Drop adrress. This information allows the Master to perform alarm reporting functions in a multipoint configuration. This object allows the master unit to add remote units from its network table. To add a remote unit to the Master's network table SET this object and specifiy the Serial Number of the unit in the first 16 locations in the OCTET STRING, and the Drop address(00 to 31) in the last 2 locations of the OCTET STRING. Remote alarm reporting will work in DDS1 only. Reading this object will report the last serial/address added or deleted.
OCTET STRING (SIZE(18))