MIB Viewer

sc5520DisableAllRemoteAlarms

OBJECT-TYPE
1.3.6.1.4.1.498.8.3.3.1.7
Access
read-write
Status
obsolete
Sub-identifiers
0
Disable All Remote Alarms tells the master (SC5520) how to configure the remote units (nms520) in a multipoint configuration with respect to alarm reporting. The master unit maintains alarm information about the remote units in its network. This object allows the master unit to disable alarm reporting on all of the remote units in its network. To disable all remote units from reporting alarms SET this object and specifiy disable(2). Reading this object indicates the modem is operating normally
INTEGER { normal(1), disable(2) }