sc5520DiagBitErrors

OBJECT-TYPE
1.3.6.1.4.1.498.8.3.6.1.4
Access
read-only
Status
mandatory
Sub-identifiers
0
The bit errors of the last diagnostic test that involved a Selftest pattern. Reading bit errors while a diagnostic test in running will cause the unit to drop out of test and invalidate the bit errors. Bit errors should be read only after the test is completed. The valid range for bit errors is 0 to 1,023, 65535 will be returned if for any reason the test was terminated early.