MIB Viewer

sc5520SwitchActiveFirmware

OBJECT-TYPE
1.3.6.1.4.1.498.8.3.8.1.6
Access
read-write
Status
mandatory
Sub-identifiers
0
This object is used to switch the active executing firmware from the version in sc5520ActiveRev to the version in sc5520StoredRev. When a switchActive(2) is set (write only) the element will: 1) reboot 2) uncompress stored code into active area 3) perform checksum on active area 4) Set sc5520StoredStatus object to indicate results 5) If succesfull: update sc5520ActiveFirmwareRev and sc5520StoredFirmwareRev and begin executing If failed: replace active area with previous revision The switchNorm(1) enumeration will always be read. Setting switchActive(2) when the sc5520StoredStatus is not statOK(3) will result in an error.
INTEGER { switchNorm(1), switchActive(2) }