MIB Viewer

sigChanEQsigCircuitSwitchedK

OBJECT-TYPE
1.3.6.1.4.1.562.2.4.1.115.2.11.1.6
Access
read-write
Status
mandatory
Sub-identifiers
0
This attribute specifies the maximum number of sequentially numbered I frames (that is, window size (k)) that may be unacknowledged at any given time for a SAP supporting primary rate (64kbit/sec) signalling.
Unsigned32 (1..127)