MIB Viewer

lpE1RxMultifrmRaiAlarm

OBJECT-TYPE
1.3.6.1.4.1.562.2.4.1.12.8.17.1.2
Access
read-only
Status
mandatory
Sub-identifiers
0
This attribute displays whether a multiframe RAI (remote alarm indicator) alarm state has been entered. A multiframe RAI alarm state is entered when a multiframe RAI alarm indicator (bit 6 of timeslot 16 in frame 0 is set to a one) is observed and accumulated for 2.5 seconds +/- 0.5 seconds. If the multiframe RAI indicator is intermittently received, the multiframe RAI defect accumulator is decremented at a rate of 1/10 of the incrementing rate (alarm integration ratio of 1/10), with all measurements based on a 200 ms polling cycle. The multiframe RAI alarm condition is cleared when the multiframe RAI alarm indication is not received for 10 seconds +/- 0.5 seconds. The multiframe RAI alarm is usually an indication that the far end facility is unable to gain multiframe synchronization. The 8pE1Atm card does not support the multiframe RAI alarm.
INTEGER { on(0), off(1) }