MIB Viewer

trkHighSpeedAlarmThreshold

OBJECT-TYPE
1.3.6.1.4.1.562.2.4.1.60.109.1.4
Access
read-write
Status
mandatory
Sub-identifiers
0
This attribute specifies the upper end of the range of normal speeds for this Trunk. If the measuredSpeedToIf exceeds this value the Trunk component generates a SET alarm. When the measuredSpeedToIf returns to or falls below the value of this attribute, the Trunk component will generate a CLEAR alarm.
Unsigned32 (1..4294967295)