MIB Viewer

ds0dpDiagDropLoop

OBJECT-TYPE
1.3.6.1.4.1.644.2.4.2.6.2.1.1.5
Access
read-write
Status
current
Sub-identifiers
0
Determines the current latching DS0 Dataport loopback code on the STP drop side (4 wire anolog side) for this port. In order to turn on a loop, the port must be configured In Service with a Connection. off (0) - indicates drop side loopback is disabled ocu (40) - triggers the DS0DP to send a standard DDS OCU loop code towards the drop side. csu (41) - triggers the DS0DP to send a standard DDS CSU loop code towards the drop side. ds0ToDrop (42) - loops the DS0 data towards the drop side. local (43) - the STP/PATCH PANEL output data enters the DS0DP and is looped back toward the four-wire drop. Also, the DS0-DP sends the DDS Mux-Out-Of-Sync-Code in place of the four-wire loop data towards the network. ds0FromDrop (49) - loops the DS0 data from the drop side.
INTEGER { off (0), ocu (40), csu (41), ds0ToDrop (42), local(43), ds0FromDrop (49) }