MIB Viewer

radioRslBelowThresholdParameters

OBJECT-TYPE
1.3.6.1.4.1.7262.1.19.4.10
Access
read-write
Status
mandatory
Sub-identifiers
0
A read-write string: The threshold in dBm and the number of seconds threshold are programmed by the user. An example of the format of the string is as follows: '-75 10'. The first parameter power level in dBm, the second is the time in seconds that the threshold must be exceeded. In this example the threshold -75 dBm and the time is set to 10 seconds. The single quote marks i.e. ' ' are not used in the command.
DisplayString ( SIZE ( 0 .. 24 ) )