vsmSigChanEmWinkOutWinkWaitMax

OBJECT-TYPE
1.3.6.1.4.1.800.2.26.2.14.1.5
Access
read-write
Status
mandatory
Sub-identifiers
0
Specifies the time, in milliseconds, to wait to detect a wink of the M-lead after seizure of the E-lead during an outgoing call. If the wink signal is not received within this time period, it is considered an error and the call will not connect. For more information, please see the following CLI command: voice signaling channel slot/port/startChannel-endChannel emw out wink wait maximum (5..60000)
INTEGER (5..60000)