starCardTempOverheat

NOTIFICATION-TYPE
1.3.6.1.4.1.8164.2.1
Status
current
Sub-identifiers
0
The card has reached a temperature beyond its safe operating range. Probable Cause: External temperature is too high; One or more fan failures; blockages the prevent fan air inflow/outflow. Action to be Taken: Inspect chassis for any item that may be blocking chassis air flow. Verify adjacent equipment is not obstructing air flow. Verify that the fans are running via the CLI/EMS. Check air filters. Check chassis maintenance schedule to see if chassis needs routine air filter replacement. Verify room temperature is within acceptable operating conditions. Clear Condition: This condition is cleared when the card reaches its operating temperature range or is removed from the system. Condition Clear Alarm: This condition is cleared by a starCardTempOK notification. This is not applicable to QVPC-SI and QVPC-DI