fclFraLpFecnBecnThreshold

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.20.13.1.1.6
Access
read-write
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object is the input resource threshold over which bits FECN (Forward Explicit Congestion Notification) of input frames and BECN (Backward Explicit Congestion Notification) of output frames are set to 1. The possible values are : '2..98'. The thresholds must be set as following : fclFraLpGroupingThreshold < fclFraLpFecnBecnThreshold < fclFraLpDeDiscardThreshold < fclFraLpAllDiscardThreshold. The default value is '10'.
INTEGER (2..98)