fcmMgfActPassword

OBJECT-TYPE
1.3.6.1.4.1.866.20.1.3.1.1.1.3
Access
read-write
Status
mandatory
Source
PCE-MIB
Sub-identifiers
0
The value of this object is the password needed to enable this management function. This password takes place in the call user data of a call to this management function. It must contains 1 to 6 alphanumeric characters (except for 'alarm' which can not be called and then does not use a password). The default values are : trafficGeneration : GG, observation : OO, statistics : SS, outstandingEvents : EE, fileTransfer : TT, telemaintenance : MM, alarm : (empty), userInterface : RR, billing : TX, extendedStatistics : SC, exploitationAccess : PP.