MIB Viewer

ifOtnMonPmRxAlarmIndicationSignal

OBJECT-TYPE
1.3.6.1.4.1.8708.2.55.2.4.1.1.9
Access
read-only
Status
current
Sub-identifiers
0
Rx Alarm indication signal (AIS), Monitored overhead: ODUk-PM-AIS Direction: Received from the associated physical interface and, unless the ODUk is terminated, the AIS is sent towards the board-internal G.805 Matrix. Reference: 16.5.1 G.709, 15.8.2.2.5 G.709, 6.2.3.2 G.798 Values: alarm: The ODUk-PM-AIS overhead is declared as active according to the G.798 processing rules ok: The ODUk-PM-AIS overhead is declared as inactive according to the G.798 processing rules
FaultStatusWithNA