MIB Viewer

LUM-AUX-MIB

284 objects
The auxiliary equipment MIB. - General - Parameters for SNMP managed equipment - Fiber protection interfaces - Node table for TM2000. - Equipment table for TM2000.
OIDNameAccessStatusDescription
1.3.6.1.4.1.8708.1.1.29IdentitylumAuxMIBModuleThe auxiliary equipment MIB. - General - Parameters for SNMP managed equipment - Fiber protection interfaces - Node table for TM2000. - Equipment table for TM2…
1.3.6.1.4.1.8708.2.29.1NodelumAuxConfs
1.3.6.1.4.1.8708.2.29.1.1NodelumAuxGroups
1.3.6.1.4.1.8708.2.29.1.1.1GroupauxGeneralGroupdeprecatedThe aux general objects.
1.3.6.1.4.1.8708.2.29.1.1.2GroupauxSnmpGroupdeprecatedThe aux equipment objects.
1.3.6.1.4.1.8708.2.29.1.1.3GroupauxFxIfGroupdeprecatedThe aux OAS module objects.
1.3.6.1.4.1.8708.2.29.1.1.4GroupauxEquipmentGroupdeprecatedThe aux OAS module objects.
1.3.6.1.4.1.8708.2.29.1.1.5GroupauxFxIfGroupV2currentThe aux OAS module objects (4.0).
1.3.6.1.4.1.8708.2.29.1.1.6GroupauxEquipmentGroupV2deprecatedThe aux OAS module objects (4.0).
1.3.6.1.4.1.8708.2.29.1.1.7GroupauxRamanIfGroupV1deprecatedThe aux RAMAN module objects (6.1).
1.3.6.1.4.1.8708.2.29.1.1.8GroupauxRamanSafetyGroupV1deprecatedThe aux RAMAN module objects (6.1).
1.3.6.1.4.1.8708.2.29.1.1.9GroupauxEquipmentGroupV3deprecatedThe aux equipment module objects (6.1).
1.3.6.1.4.1.8708.2.29.1.1.10GroupauxSnmpGroupV2currentThe aux snmp objects V2 (6.1).
1.3.6.1.4.1.8708.2.29.1.1.11GroupauxRamanSafetyGroupV2currentThe aux safety module objects (6.1).
1.3.6.1.4.1.8708.2.29.1.1.12GroupauxPEIfGroupV1currentthe aux PE If module objects (6.1).
1.3.6.1.4.1.8708.2.29.1.1.13GroupauxEquipmentGroupV4deprecatedThe aux equipment module objects (6.1).
1.3.6.1.4.1.8708.2.29.1.1.14GroupauxEquipmentGroupV5currentThe aux equipment module objects (6.1).
1.3.6.1.4.1.8708.2.29.1.1.15GroupauxNodeGroupV1currentThe aux node module objects, e.g. used for TM2000 (6.1).
1.3.6.1.4.1.8708.2.29.1.1.16GroupauxRamanIfGroupV2currentThe aux RAMAN module objects (6.1).
1.3.6.1.4.1.8708.2.29.1.1.17GroupauxGeneralGroupV2currentThe aux general objects.
1.3.6.1.4.1.8708.2.29.1.1.18GroupauxCabinetGroupV1currentThe aux Cabinet module objects (28.1).
1.3.6.1.4.1.8708.2.29.1.1.19GroupauxFanGroupV1currentThe aux Fan module objects (27.1).
1.3.6.1.4.1.8708.2.29.1.1.20GroupauxFanGroupGroupV1currentThe aux FanGroup module objects (27.1).
1.3.6.1.4.1.8708.2.29.1.2NodelumAuxCompl
1.3.6.1.4.1.8708.2.29.1.2.1CompliancelumAuxBasicComplV1deprecatedBasic implementation requirements for the aux MIB v1. (3.1)
1.3.6.1.4.1.8708.2.29.1.2.2CompliancelumAuxBasicComplV2deprecatedBasic implementation requirements for the aux MIB v2. (4.0)
1.3.6.1.4.1.8708.2.29.1.2.3CompliancelumAuxBasicComplV3deprecatedBasic implementation requirements for the aux MIB v3. (6.1)
1.3.6.1.4.1.8708.2.29.1.2.4CompliancelumAuxBasicComplV4deprecatedBasic implementation requirements for the aux MIB v4. (6.1)
1.3.6.1.4.1.8708.2.29.1.2.5CompliancelumAuxBasicComplV5deprecatedBasic implementation requirements for the aux MIB v5. (6.1)
1.3.6.1.4.1.8708.2.29.1.2.6CompliancelumAuxBasicComplV6deprecatedBasic implementation requirements for the aux MIB v5. (6.1)
1.3.6.1.4.1.8708.2.29.1.2.7CompliancelumAuxBasicComplV7deprecatedBasic implementation requirements for the aux MIB v7. (27.1)
1.3.6.1.4.1.8708.2.29.1.2.8CompliancelumAuxBasicComplV8currentBasic implementation requirements for the aux MIB v8. (30.1)
1.3.6.1.4.1.8708.2.29.2NodelumAuxMIBObjects
1.3.6.1.4.1.8708.2.29.2.1NodeauxGeneral
1.3.6.1.4.1.8708.2.29.2.1.1ScalarauxGeneralTestAndIncrread-writecurrentProtection against simultaneous access from multiple managers. See SNMPv2-TC.
1.3.6.1.4.1.8708.2.29.2.1.2ScalarauxGeneralStateLastChangeTimeread-onlycurrentThe time when the state of the MIB was last changed.
1.3.6.1.4.1.8708.2.29.2.1.3ScalarauxGeneralConfigLastChangeTimeread-onlycurrentThe time when the configuration of the MIB was last changed.
1.3.6.1.4.1.8708.2.29.2.1.4ScalarauxGeneralSnmpTableSizeread-onlycurrentNumber of rows available in the table for snmp managed equipment.
1.3.6.1.4.1.8708.2.29.2.1.5ScalarauxGeneralFxIfTableSizeread-onlycurrentNumber of rows available in the fiber protections interface table.
1.3.6.1.4.1.8708.2.29.2.1.6ScalarauxGeneralAuxEquipmentTableSizeread-onlycurrentNumber of rows available in the fiber protections interface table.
1.3.6.1.4.1.8708.2.29.2.1.7ScalarauxGeneralRamanIfTableSizeread-onlycurrentNumber of rows available in the raman amplifier interface table.
1.3.6.1.4.1.8708.2.29.2.1.8ScalarauxGeneralRamanSafetyTableSizeread-onlycurrentNumber of rows available in the raman amplifier safety table.
1.3.6.1.4.1.8708.2.29.2.1.9ScalarauxGeneralPEIfTableSizeread-onlycurrentNumber of rows available in the raman amplifier interface table.
1.3.6.1.4.1.8708.2.29.2.1.10ScalarauxGeneralNodeTableSizeread-onlycurrentNumber of rows available in the Node table.
1.3.6.1.4.1.8708.2.29.2.1.11ScalarauxGeneralCabinetTableSizeread-onlycurrentNumber of rows available in the Cabinet table.
1.3.6.1.4.1.8708.2.29.2.1.12ScalarauxGeneralFanTableSizeread-onlycurrentNumber of rows available in the Fan table.
1.3.6.1.4.1.8708.2.29.2.1.13ScalarauxGeneralFanGroupTableSizeread-onlycurrentNumber of rows available in the FanGroup table.
1.3.6.1.4.1.8708.2.29.2.2NodeauxSnmpList
1.3.6.1.4.1.8708.2.29.2.2.1TableauxSnmpTablenot-accessiblecurrentThe list of SNMP managed equipment.
1.3.6.1.4.1.8708.2.29.2.2.1.1RowauxSnmpEntrynot-accessiblecurrentAn entry in the SNMP managed equipment list.
1.3.6.1.4.1.8708.2.29.2.2.1.1.1ColumnauxSnmpIndexread-onlycurrentAn arbitrary index assigned to each equipment.
1.3.6.1.4.1.8708.2.29.2.2.1.1.2ColumnauxSnmpNameread-onlycurrentThe name of the SNMP managed equipment.
1.3.6.1.4.1.8708.2.29.2.2.1.1.3ColumnauxSnmpDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.29.2.2.1.1.4ColumnauxSnmpAddressread-writecurrentThe IP address for the SNMP managed equipment.
1.3.6.1.4.1.8708.2.29.2.2.1.1.5ColumnauxSnmpVersionread-writecurrentSNMP protocol version.
1.3.6.1.4.1.8708.2.29.2.2.1.1.6ColumnauxSnmpPortread-writecurrentThe port number for the SNMP managed equipment.
1.3.6.1.4.1.8708.2.29.2.2.1.1.7ColumnauxSnmpReadCommunityread-writecurrentThe community string to use when reading information from the SNMP managed equipment.
1.3.6.1.4.1.8708.2.29.2.2.1.1.8ColumnauxSnmpWriteCommunityread-writecurrentThe community string to use when configuring the SNMP managed equipment.
1.3.6.1.4.1.8708.2.29.2.2.1.1.9ColumnauxSnmpAdminStatusread-writecurrentThe administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended f…
1.3.6.1.4.1.8708.2.29.2.2.1.1.10ColumnauxSnmpOperStatusread-onlycurrentThe operational state for the object. notPresent - The HW related to the object is not available down - The object is de-activated or there are faults preventi…
1.3.6.1.4.1.8708.2.29.2.2.1.1.11ColumnauxSnmpInvPhysIndexOrZeroread-onlycurrentThe row in the invPhysTable for this interface. Set to 0 if not known.
1.3.6.1.4.1.8708.2.29.2.2.1.1.12ColumnauxSnmpHostUnreachableread-onlycurrentCan not contact the remote external equipment. Check address and community strings. A(ctivation): Contact lost D(e-activation): Contact stablished again
1.3.6.1.4.1.8708.2.29.2.2.1.1.13ColumnauxSnmpSnmpErrorread-onlycurrentCan not login to the remote external equipment A(ctivation): Contact lost D(e-activation): Contact stablished again
1.3.6.1.4.1.8708.2.29.2.2.1.1.14ColumnauxSnmpUnexpectedEquipmentTyperead-onlycurrentThe remote external equipment is not of the expected type. A(ctivation): Wrong equipment detected D(e-activation): Expected equipment detected
1.3.6.1.4.1.8708.2.29.2.2.1.1.15ColumnauxSnmpInconsistentConfigurationread-onlycurrentChanges in the configuration of the remote equipment has been detected. This could happen if some other SNMP-manager is manipulating the configuration, or the …
1.3.6.1.4.1.8708.2.29.2.2.1.1.16ColumnauxSnmpConfigurationProblemread-onlycurrentThe SNMP-manager can not configure the remote equipment. A possible cause could be that the writeCommunity does not match the remote equipment. A(ctivation): A…
1.3.6.1.4.1.8708.2.29.2.3NodeauxFxIfList
1.3.6.1.4.1.8708.2.29.2.3.1TableauxFxIfTablenot-accessiblecurrentThe list of OAS modules.
1.3.6.1.4.1.8708.2.29.2.3.1.1RowauxFxIfEntrynot-accessiblecurrentAn entry in the OAS module list.
1.3.6.1.4.1.8708.2.29.2.3.1.1.1ColumnauxFxIfIndexread-onlycurrentAn arbitrary index assigned to each configuration equipment.
1.3.6.1.4.1.8708.2.29.2.3.1.1.2ColumnauxFxIfNameread-onlycurrentThe name of the FxIf.
1.3.6.1.4.1.8708.2.29.2.3.1.1.3ColumnauxFxIfDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.29.2.3.1.1.4ColumnauxFxIfSubrackread-onlycurrentThe number of the subrack where the interface is located.
1.3.6.1.4.1.8708.2.29.2.3.1.1.5ColumnauxFxIfSlotread-onlycurrentThe number of the slot where the interface is located.
1.3.6.1.4.1.8708.2.29.2.3.1.1.6ColumnauxFxIfTxPortread-onlycurrentThe number of the port where the interface is located.
1.3.6.1.4.1.8708.2.29.2.3.1.1.7ColumnauxFxIfRxPortread-onlycurrentThe number of the port where the interface is located.
1.3.6.1.4.1.8708.2.29.2.3.1.1.8ColumnauxFxIfInvPhysIndexOrZeroread-onlycurrentThe row in the invPhysTable for this interface. Set to 0 if not known.
1.3.6.1.4.1.8708.2.29.2.3.1.1.9ColumnauxFxIfAdminStatusread-writecurrentThe administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended f…
1.3.6.1.4.1.8708.2.29.2.3.1.1.10ColumnauxFxIfOperStatusread-onlycurrentThe operational state for the interface. notPresent - The interface is not available. down - The interface is de-activated or there are faults preventing it fr…
1.3.6.1.4.1.8708.2.29.2.3.1.1.11ColumnauxFxIfRxPowerLevelread-onlycurrentThe received power level in units of 0.1 dBm.
1.3.6.1.4.1.8708.2.29.2.3.1.1.12ColumnauxFxIfLossOfSignalThresholdread-writecurrentThe lower threshold for received power level in units of 0.1 dBm. Note: Depending on the type of board and interface the value range may vary.
1.3.6.1.4.1.8708.2.29.2.3.1.1.13ColumnauxFxIfLossOfSignalread-onlycurrentLoss of signal. Applicable for all signal formats. A(ctivation): Active loss of signal HW indication. D(e-activation): Inactive loss of signal HW indication.
1.3.6.1.4.1.8708.2.29.2.3.1.1.14ColumnauxFxIfObjectPropertyread-onlycurrentProperty mask.
1.3.6.1.4.1.8708.2.29.2.4NodeauxEquipmentList
1.3.6.1.4.1.8708.2.29.2.4.1TableauxEquipmentTablenot-accessiblecurrentThe list of OAS modules.
1.3.6.1.4.1.8708.2.29.2.4.1.1RowauxEquipmentEntrynot-accessiblecurrentAn entry in the OAS module list.
1.3.6.1.4.1.8708.2.29.2.4.1.1.1ColumnauxEquipmentIndexread-onlycurrentAn arbitrary index assigned to each configuration equipment.
1.3.6.1.4.1.8708.2.29.2.4.1.1.2ColumnauxEquipmentNameread-onlycurrentThe name of the equipment.
1.3.6.1.4.1.8708.2.29.2.4.1.1.3ColumnauxEquipmentDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.29.2.4.1.1.4ColumnauxEquipmentSubrackread-onlycurrentThe number of the subrack where the interface is located.
1.3.6.1.4.1.8708.2.29.2.4.1.1.5ColumnauxEquipmentSlotread-onlycurrentThe number of the slot where the interface is located.
1.3.6.1.4.1.8708.2.29.2.4.1.1.6ColumnauxEquipmentAdminStatusread-writecurrentThe administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended f…
1.3.6.1.4.1.8708.2.29.2.4.1.1.7ColumnauxEquipmentOperStatusread-onlycurrentThe operational state for the interface. notPresent - The interface is not available. down - The interface is de-activated or there are faults preventing it fr…
1.3.6.1.4.1.8708.2.29.2.4.1.1.8ColumnauxEquipmentPowerFailureread-onlycurrentRemote equipment reports power failure. A(ctivation): Power failure detected D(e-activation): Power failure no longer active
1.3.6.1.4.1.8708.2.29.2.4.1.1.9ColumnauxEquipmentFanProblemread-onlycurrentRemote equipment report problem with built-in fan unit. A(ctivation): Fan problem detected D(e-activation): Fan problem no longer active
1.3.6.1.4.1.8708.2.29.2.4.1.1.10ColumnauxEquipmentObjectPropertyread-onlycurrentProperty mask
1.3.6.1.4.1.8708.2.29.2.4.1.1.11ColumnauxEquipmentPumpsEolread-onlycurrentShows the end-of-life status of the HW. For the RAMAN, the alarm is active if the current of any of the pumps has reached its end-of-life threshold.
1.3.6.1.4.1.8708.2.29.2.4.1.1.12ColumnauxEquipmentSelfTestFailureread-onlycurrentIndicates if the built-in self-test failed.
1.3.6.1.4.1.8708.2.29.2.4.1.1.13ColumnauxEquipmentAmbientTempread-onlycurrentShows the ambient temperature of the equipment.
1.3.6.1.4.1.8708.2.29.2.4.1.1.14ColumnauxEquipmentRebootEquipmentread-onlycurrentExecuting this procedure will initiate a reboot of the auxiliary equipment.
1.3.6.1.4.1.8708.2.29.2.4.1.1.15ColumnauxEquipmentPowerAMissingread-onlycurrentStatus of 1U Power A missing Alarm.
1.3.6.1.4.1.8708.2.29.2.4.1.1.16ColumnauxEquipmentPowerBMissingread-onlycurrentStatus of 1U Power B missing Alarm.
1.3.6.1.4.1.8708.2.29.2.4.1.1.17ColumnauxEquipmentConfigurationMismatchread-onlycurrentA configuration request has failed and there might now be a mismatch in configuration between tm3000 and external system. A: A configuration request failed. D:…
1.3.6.1.4.1.8708.2.29.2.5NodeauxRamanIfList
1.3.6.1.4.1.8708.2.29.2.5.1TableauxRamanIfTablenot-accessiblecurrentThe list of RAMAN i/f.
1.3.6.1.4.1.8708.2.29.2.5.1.1RowauxRamanIfEntrynot-accessiblecurrentAn entry in the RAMAN i/f list.
1.3.6.1.4.1.8708.2.29.2.5.1.1.1ColumnauxRamanIfIndexread-onlycurrentAn arbitrary index assigned to each configuration equipment.
1.3.6.1.4.1.8708.2.29.2.5.1.1.2ColumnauxRamanIfNameread-onlycurrentThe name of the FxIf.
1.3.6.1.4.1.8708.2.29.2.5.1.1.3ColumnauxRamanIfDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.29.2.5.1.1.4ColumnauxRamanIfSubrackread-onlycurrentThe number of the subrack where the interface is located.
1.3.6.1.4.1.8708.2.29.2.5.1.1.5ColumnauxRamanIfSlotread-onlycurrentThe number of the slot where the interface is located.
1.3.6.1.4.1.8708.2.29.2.5.1.1.6ColumnauxRamanIfTxPortread-onlycurrentThe number of the port where the interface is located.
1.3.6.1.4.1.8708.2.29.2.5.1.1.7ColumnauxRamanIfRxPortread-onlycurrentThe number of the port where the interface is located.
1.3.6.1.4.1.8708.2.29.2.5.1.1.8ColumnauxRamanIfInvPhysIndexOrZeroread-onlycurrentThe row in the invPhysTable for this interface. Set to 0 if not known.
1.3.6.1.4.1.8708.2.29.2.5.1.1.9ColumnauxRamanIfAdminStatusread-writecurrentThe administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended f…
1.3.6.1.4.1.8708.2.29.2.5.1.1.10ColumnauxRamanIfOperStatusread-onlycurrentThe operational state for the interface. notPresent - The interface is not available. down - The interface is de-activated or there are faults preventing it fr…
1.3.6.1.4.1.8708.2.29.2.5.1.1.11ColumnauxRamanIfObjectPropertyread-onlycurrentProperty mask.
1.3.6.1.4.1.8708.2.29.2.5.1.1.12ColumnauxRamanIfModuleOperationModeread-onlycurrentModule operational mode.
1.3.6.1.4.1.8708.2.29.2.5.1.1.13ColumnauxRamanIfPumpsOperationModeread-createcurrentPumps operational mode.
1.3.6.1.4.1.8708.2.29.2.5.1.1.14ColumnauxRamanIfPumpsOperationModeConfigread-onlycurrentConfigure pumps operational mode.
1.3.6.1.4.1.8708.2.29.2.5.1.1.15ColumnauxRamanIfLineFiberTyperead-writecurrentLine fiber type (for adaptive gain flattening).
1.3.6.1.4.1.8708.2.29.2.5.1.1.16ColumnauxRamanIfAutoRestartProcTimeread-writecurrentAutomatic Restart Procedure restart time.
1.3.6.1.4.1.8708.2.29.2.5.1.1.17ColumnauxRamanIfArpPauseStatusread-onlycurrentShows whether the Raman amplifier is in Automatic Restart Procedure restart state.
1.3.6.1.4.1.8708.2.29.2.5.1.1.18ColumnauxRamanIfPumpsStatusread-onlycurrentShows whether the pumps are active or not.
1.3.6.1.4.1.8708.2.29.2.5.1.1.19ColumnauxRamanIfTotalPumpsPowerread-onlycurrentThe total power of the pumps.
1.3.6.1.4.1.8708.2.29.2.5.1.1.20ColumnauxRamanIfPump1WantedPowerread-writecurrentThe wanted power of the higher pump. Used for manual configuration.
1.3.6.1.4.1.8708.2.29.2.5.1.1.21ColumnauxRamanIfPump1ActualPowerread-onlycurrentThe actual power of the higher pump.
1.3.6.1.4.1.8708.2.29.2.5.1.1.22ColumnauxRamanIfPump1Currentread-onlycurrentThe current of the higher pump.
1.3.6.1.4.1.8708.2.29.2.5.1.1.23ColumnauxRamanIfPump1Temperatureread-onlycurrentThe temperature of the higher pump.
1.3.6.1.4.1.8708.2.29.2.5.1.1.24ColumnauxRamanIfPump2WantedPowerread-writecurrentThe wanted power of the higher pump. Used for manual configuration.
1.3.6.1.4.1.8708.2.29.2.5.1.1.25ColumnauxRamanIfPump2ActualPowerread-onlycurrentThe actual power of the higher pump.
1.3.6.1.4.1.8708.2.29.2.5.1.1.26ColumnauxRamanIfPump2Currentread-onlycurrentThe current of the higher pump.
1.3.6.1.4.1.8708.2.29.2.5.1.1.27ColumnauxRamanIfPump2Temperatureread-onlycurrentThe temperature of the higher pump.
1.3.6.1.4.1.8708.2.29.2.5.1.1.28ColumnauxRamanIfWantedGainread-writecurrentThe wanted gain. Used in gain-mode.
1.3.6.1.4.1.8708.2.29.2.5.1.1.29ColumnauxRamanIfActualGainread-onlycurrentThe actual gain. Used in gain-mode.
1.3.6.1.4.1.8708.2.29.2.5.1.1.30ColumnauxRamanIfReceivedPowerLevelread-onlycurrentThe received power on the line i/f.
1.3.6.1.4.1.8708.2.29.2.5.1.1.31ColumnauxRamanIfReflectionPowerLevelread-onlycurrentThe received reflection power.
1.3.6.1.4.1.8708.2.29.2.5.1.1.32ColumnauxRamanIfReflectionPowerRatioread-onlycurrentThe received reflection power in relation to the power of the pumps.
1.3.6.1.4.1.8708.2.29.2.5.1.1.33ColumnauxRamanIf1510BandReceivedPowerLevelread-onlycurrentThe received power in the 1510 band.
1.3.6.1.4.1.8708.2.29.2.5.1.1.34ColumnauxRamanIfOscReceivedPowerLevelread-onlycurrentThe received power of the OSC channel.
1.3.6.1.4.1.8708.2.29.2.5.1.1.35ColumnauxRamanIfAPRStateread-onlycurrentShows the state of the Automatic Power Reduction procedure
1.3.6.1.4.1.8708.2.29.2.5.1.1.36ColumnauxRamanIfOscDitherStateread-onlycurrentShows the dithering state of the Optical Supervisiory Channel.
1.3.6.1.4.1.8708.2.29.2.5.1.1.37ColumnauxRamanIfLineLossOfSignalread-onlycurrentThe input line signal is lost.
1.3.6.1.4.1.8708.2.29.2.5.1.1.38ColumnauxRamanIfOscDitherLosread-onlycurrentThe dithering of the OSC channel is lost.
1.3.6.1.4.1.8708.2.29.2.5.1.1.39ColumnauxRamanIfHighBackReflectionread-onlycurrentHigh back-reflection power detected.
1.3.6.1.4.1.8708.2.29.2.5.1.1.40ColumnauxRamanIfHighLineOutputPowerread-onlycurrentHigh line output power is detected. The power is decreased not to exceed the maximum power
1.3.6.1.4.1.8708.2.29.2.5.1.1.41ColumnauxRamanIfLowLineOutputPowerread-onlycurrentLow output power is detected.
1.3.6.1.4.1.8708.2.29.2.5.1.1.42ColumnauxRamanIfModuleTempTooHighread-onlycurrentToo high ambient temperature of the amplifier module causing shut down.
1.3.6.1.4.1.8708.2.29.2.5.1.1.43ColumnauxRamanIfModuleTempHighread-onlycurrentHigh ambient temperature of the amplifier module. Crossed warning threshold
1.3.6.1.4.1.8708.2.29.2.5.1.1.44ColumnauxRamanIfPumpsTempTooHighread-onlycurrentToo high temperature of the pumps causing shut down.
1.3.6.1.4.1.8708.2.29.2.5.1.1.45ColumnauxRamanIfPumpsTempHighread-onlycurrentHigh temperature of the pumps. Crossed warning threshold.
1.3.6.1.4.1.8708.2.29.2.5.1.1.46ColumnauxRamanIfAprShutdownread-onlycurrentShows if the pumps have been shutdown according to any of the APR or ALS schemes.
1.3.6.1.4.1.8708.2.29.2.5.1.1.47ColumnauxRamanIfLineFiberDeterioratedread-onlycurrentThe quality of the line fiber has changed (deteriorated).
1.3.6.1.4.1.8708.2.29.2.5.1.1.48ColumnauxRamanIf1510BandPowerLosread-onlycurrentThe power of the 1510 band has been lost.
1.3.6.1.4.1.8708.2.29.2.5.1.1.49ColumnauxRamanIfManualRestartTrialread-onlycurrentExecuting this procedure initiates a manual restart trial.
1.3.6.1.4.1.8708.2.29.2.5.1.1.50ColumnauxRamanIfModuleTempread-onlycurrentShows the ambient temperature of the amplifier module.
1.3.6.1.4.1.8708.2.29.2.5.1.1.51ColumnauxRamanIfTxSignalStatusread-onlycurrentThe operational state for outgoing (TX) signal of the interface. down - A fault that would lead to a protection switch has occurred. degraded - The signal qual…
1.3.6.1.4.1.8708.2.29.2.5.1.1.52ColumnauxRamanIfRxSignalStatusread-onlycurrentThe operational state for incoming (RX) signal of the interface. down - A major fault has occurred degraded - The signal quality is impaired. up - The signal i…
1.3.6.1.4.1.8708.2.29.2.6NodeauxRamanSafetyList
1.3.6.1.4.1.8708.2.29.2.6.1TableauxRamanSafetyTablenot-accessiblecurrentThe list of safety modules.
1.3.6.1.4.1.8708.2.29.2.6.1.1RowauxRamanSafetyEntrynot-accessiblecurrentAn entry in the safety list.
1.3.6.1.4.1.8708.2.29.2.6.1.1.1ColumnauxRamanSafetyIndexread-onlycurrentAn arbitrary index assigned to each configuration equipment.
1.3.6.1.4.1.8708.2.29.2.6.1.1.2ColumnauxRamanSafetyNameread-onlycurrentThe name of the ramanSafety object.
1.3.6.1.4.1.8708.2.29.2.6.1.1.3ColumnauxRamanSafetyDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.29.2.6.1.1.4ColumnauxRamanSafetySubrackread-onlycurrentThe number of the subrack where the interface is located.
1.3.6.1.4.1.8708.2.29.2.6.1.1.5ColumnauxRamanSafetySlotread-onlycurrentThe number of the slot where the interface is located.
1.3.6.1.4.1.8708.2.29.2.6.1.1.6ColumnauxRamanSafetyTxPortread-onlycurrentThe number of the port where the interface is located.
1.3.6.1.4.1.8708.2.29.2.6.1.1.7ColumnauxRamanSafetyRxPortread-onlycurrentThe number of the port where the interface is located.
1.3.6.1.4.1.8708.2.29.2.6.1.1.8ColumnauxRamanSafetyInvPhysIndexOrZeroread-onlycurrentThe row in the invPhysTable for this interface. Set to 0 if not known.
1.3.6.1.4.1.8708.2.29.2.6.1.1.9ColumnauxRamanSafetyObjectPropertyread-onlycurrentProperty mask.
1.3.6.1.4.1.8708.2.29.2.6.1.1.10ColumnauxRamanSafetyShutDownAtInputLossread-createcurrentThis parameter controls whether the amplifier will shut down in the following situation: Loss of input power
1.3.6.1.4.1.8708.2.29.2.6.1.1.11ColumnauxRamanSafetyShutDownAtHighTempread-createcurrentThis parameter controls whether the amplifier will shut down in the following situation: The temperature of the pumps or the modules is high.
1.3.6.1.4.1.8708.2.29.2.6.1.1.12ColumnauxRamanSafetyShutDownAtHighBackReflectionread-createcurrentThis parameter controls whether the amplifier will shut down in the following situation: There is a high back reflection of power, indication that there might …
1.3.6.1.4.1.8708.2.29.2.6.1.1.13ColumnauxRamanSafetyHighBackReflectionThresholdread-writecurrentThe threshold for back reflection causing amplifier pumps to shut down. The threshold is a ratio expressed in dB relative to the output power of the amplifier.
1.3.6.1.4.1.8708.2.29.2.6.1.1.14ColumnauxRamanSafetyShutDownAtOscLossread-createcurrentThis parameter controls whether the amplifier will shut down in the following situation: The signal from the OSC channel is lost.
1.3.6.1.4.1.8708.2.29.2.6.1.1.15ColumnauxRamanSafetyShutDownAt1510BandDropread-createcurrentThis parameter controls whether the amplifier will shut down in the following situation: The power from the 1510 band drops.
1.3.6.1.4.1.8708.2.29.2.6.1.1.16ColumnauxRamanSafetyShutDownAtInputLossConfigread-onlycurrent.
1.3.6.1.4.1.8708.2.29.2.6.1.1.17ColumnauxRamanSafetyShutDownAtHighTempConfigread-onlycurrent.
1.3.6.1.4.1.8708.2.29.2.6.1.1.18ColumnauxRamanSafetyShutDownAtHighBackReflectionConfigread-onlycurrent.
1.3.6.1.4.1.8708.2.29.2.6.1.1.19ColumnauxRamanSafetyShutDownAtOscLossConfigread-onlycurrent.
1.3.6.1.4.1.8708.2.29.2.6.1.1.20ColumnauxRamanSafetyShutDownAt1510BandDropConfigread-onlycurrent.
1.3.6.1.4.1.8708.2.29.2.6.1.1.21ColumnauxRamanSafetyPasswdread-createcurrentPassword protecting the safety parameters If password is '-' (dash), then the password control is disabled.
1.3.6.1.4.1.8708.2.29.2.6.1.1.22ColumnauxRamanSafetyPasswdConfigread-onlycurrent.
1.3.6.1.4.1.8708.2.29.2.6.1.1.23ColumnauxRamanSafety1510BandDropThresholdread-writecurrentThe threshold for OSC band drop causing pumps shut down.
1.3.6.1.4.1.8708.2.29.2.6.1.1.24ColumnauxRamanSafetyInhibitStartAtOscLossread-createcurrentThis parameter controls whether the amplifier is allowed to turn on in a situation where the OSC is missing
1.3.6.1.4.1.8708.2.29.2.6.1.1.25ColumnauxRamanSafetyInhibitStartAtOscLossConfigread-onlycurrent.
1.3.6.1.4.1.8708.2.29.2.6.1.1.26ColumnauxRamanSafetyShutDownAtLowBandDropread-createcurrentThis parameter controls whether the amplifier will shut down in the following situation: Low L-band scattering is detected.
1.3.6.1.4.1.8708.2.29.2.6.1.1.27ColumnauxRamanSafetyLowBandScatteringThresholdread-writecurrentThe threshold for safety parameter 'Shut down at L-band power drop'.
1.3.6.1.4.1.8708.2.29.2.6.1.1.28ColumnauxRamanSafetyShutDownAtLowBandDropConfigread-onlycurrent.
1.3.6.1.4.1.8708.2.29.2.6.1.1.29ColumnauxRamanSafetyAmplifierSwitchread-createcurrentEnable activating or disable of the pumps operation. When switch in Enabled mode, pumps are activated to last operation mode and power/current/gain settings
1.3.6.1.4.1.8708.2.29.2.6.1.1.30ColumnauxRamanSafetyAmplifierSwitchConfigread-onlycurrent.
1.3.6.1.4.1.8708.2.29.2.6.1.1.31ColumnauxRamanSafetyLowBandScatteringToleranceread-writecurrentThe transient tolerance (expressed in dB) for safety parameter 'Shut down at L-band drop'.
1.3.6.1.4.1.8708.2.29.2.7NodeauxPEIfList
1.3.6.1.4.1.8708.2.29.2.7.1TableauxPEIfTablenot-accessiblecurrentThe list of PE i/f.
1.3.6.1.4.1.8708.2.29.2.7.1.1RowauxPEIfEntrynot-accessiblecurrentAn entry in the PE i/f list.
1.3.6.1.4.1.8708.2.29.2.7.1.1.1ColumnauxPEIfIndexread-onlycurrentAn arbitrary index assigned to each configuration equipment.
1.3.6.1.4.1.8708.2.29.2.7.1.1.2ColumnauxPEIfNameread-onlycurrentThe name of the FxIf.
1.3.6.1.4.1.8708.2.29.2.7.1.1.3ColumnauxPEIfDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.29.2.7.1.1.4ColumnauxPEIfSubrackread-onlycurrentThe number of the subrack where the interface is located.
1.3.6.1.4.1.8708.2.29.2.7.1.1.5ColumnauxPEIfSlotread-onlycurrentThe number of the slot where the interface is located.
1.3.6.1.4.1.8708.2.29.2.7.1.1.6ColumnauxPEIfTxPortread-onlycurrentThe number of the port where the interface is located.
1.3.6.1.4.1.8708.2.29.2.7.1.1.7ColumnauxPEIfRxPortread-onlycurrentThe number of the port where the interface is located.
1.3.6.1.4.1.8708.2.29.2.7.1.1.8ColumnauxPEIfInvPhysIndexOrZeroread-onlycurrentThe row in the invPhysTable for this interface. Set to 0 if not known.
1.3.6.1.4.1.8708.2.29.2.7.1.1.9ColumnauxPEIfAdminStatusread-writecurrentThe administrative state for the interface. down - The interface should be inactive. service - The interface is activated but alarms are suppressed. Intended f…
1.3.6.1.4.1.8708.2.29.2.7.1.1.10ColumnauxPEIfOperStatusread-onlycurrentThe operational state for the interface. notPresent - The interface is not available. down - The interface is de-activated or there are faults preventing it fr…
1.3.6.1.4.1.8708.2.29.2.7.1.1.11ColumnauxPEIfObjectPropertyread-onlycurrentProperty mask.
1.3.6.1.4.1.8708.2.29.2.7.1.1.12ColumnauxPEIfPumpsOperationModeread-createcurrentIn constant power mode the desired power has to be set. In constant gain the desired output gain should be set.
1.3.6.1.4.1.8708.2.29.2.7.1.1.13ColumnauxPEIfPumpsOperationModeConfigread-onlycurrentConfigure pumps operational mode. In constant power mode the desired power has to be set. In constant gain mode the desired output gain should be set.
1.3.6.1.4.1.8708.2.29.2.7.1.1.14ColumnauxPEIfAutoRestartProcTimeread-writecurrentAutomatic Restart Procedure restart time.
1.3.6.1.4.1.8708.2.29.2.7.1.1.15ColumnauxPEIfPumpsStatusread-onlycurrentShows whether the pumps are active or not.
1.3.6.1.4.1.8708.2.29.2.7.1.1.16ColumnauxPEIfWantedPowerread-writecurrentOutput power setting for constant power operation mode.
1.3.6.1.4.1.8708.2.29.2.7.1.1.17ColumnauxPEIfWantedGainread-writecurrentRequired gain value in dB for constant gain operation mode.
1.3.6.1.4.1.8708.2.29.2.7.1.1.18ColumnauxPEIfPumpsTotalCurrentread-onlycurrentPumps total current
1.3.6.1.4.1.8708.2.29.2.7.1.1.19ColumnauxPEIfPump1Temperatureread-onlycurrentThe temperature of the higher pump.
1.3.6.1.4.1.8708.2.29.2.7.1.1.20ColumnauxPEIfActualGainread-onlycurrentThe actual gain of the Amplifier (deci-dB).
1.3.6.1.4.1.8708.2.29.2.7.1.1.21ColumnauxPEIfReceivedPowerLevelread-onlycurrentInput Power (Forward mode) (deci-dBm). Please Note: Original value of Float type was transformed to an integer, therefore the MIB value is presented in deci-dB…
1.3.6.1.4.1.8708.2.29.2.7.1.1.22ColumnauxPEIfCombinedOutPwrLevelread-onlycurrentLine Interface combined Output Power (deci-dBm). Please Note: Original value of Float type was transformed to an integer, therefore the MIB value is presented …
1.3.6.1.4.1.8708.2.29.2.7.1.1.23ColumnauxPEIfReflectionPowerLevelread-onlycurrentThe received reflection power.
1.3.6.1.4.1.8708.2.29.2.7.1.1.24ColumnauxPEIfReflectionPowerRatioread-onlycurrentThe received reflection power in relation to the power of the pumps.
1.3.6.1.4.1.8708.2.29.2.7.1.1.25ColumnauxPEIfLowBandScatteredPowerLevelread-onlycurrentThe scattered power in the L-band.
1.3.6.1.4.1.8708.2.29.2.7.1.1.26ColumnauxPEIfLineLossOfSignalread-onlycurrentThe input line signal is lost.
1.3.6.1.4.1.8708.2.29.2.7.1.1.27ColumnauxPEIfHighBackReflectionread-onlycurrentHigh back-reflection power detected.
1.3.6.1.4.1.8708.2.29.2.7.1.1.28ColumnauxPEIfAutoPowerReductionread-onlycurrentAutomatic Power Reduction
1.3.6.1.4.1.8708.2.29.2.7.1.1.29ColumnauxPEIfLowLineOutputPowerread-onlycurrentLow output power is detected.
1.3.6.1.4.1.8708.2.29.2.7.1.1.30ColumnauxPEIfModuleTempTooHighread-onlycurrentToo high ambient temperature of the amplifier module causing shut down.
1.3.6.1.4.1.8708.2.29.2.7.1.1.31ColumnauxPEIfModuleTempHighread-onlycurrentHigh ambient temperature of the amplifier module. Crossed warning threshold
1.3.6.1.4.1.8708.2.29.2.7.1.1.32ColumnauxPEIfPumpsTempTooHighread-onlycurrentToo high temperature of the pumps causing shut down.
1.3.6.1.4.1.8708.2.29.2.7.1.1.33ColumnauxPEIfPumpsTempHighread-onlycurrentHigh temperature of the pumps. Crossed warning threshold.
1.3.6.1.4.1.8708.2.29.2.7.1.1.34ColumnauxPEIfModuleTempread-onlycurrentShows the ambient temperature of the amplifier module.
1.3.6.1.4.1.8708.2.29.2.7.1.1.35ColumnauxPEIfPump2Temperatureread-onlycurrentPump #2 temperature.
1.3.6.1.4.1.8708.2.29.2.8NodeauxNodeList
1.3.6.1.4.1.8708.2.29.2.8.1TableauxNodeTablenot-accessiblecurrentThe list of Node (TM2000) stuff.
1.3.6.1.4.1.8708.2.29.2.8.1.1RowauxNodeEntrynot-accessiblecurrentAn entry in the Node list.
1.3.6.1.4.1.8708.2.29.2.8.1.1.1ColumnauxNodeIndexread-onlycurrentAn arbitrary index assigned to each configuration equipment.
1.3.6.1.4.1.8708.2.29.2.8.1.1.2ColumnauxNodeNameread-onlycurrentThe name of the Node.
1.3.6.1.4.1.8708.2.29.2.8.1.1.3ColumnauxNodeDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.29.2.8.1.1.4ColumnauxNodeIpAddressread-writecurrentThe IP address for the TM2000 node. The default value is set to 10.0.<subrack>.11 at system start-up.
1.3.6.1.4.1.8708.2.29.2.8.1.1.5ColumnauxNodePortread-writecurrentThe server port number for the TM2000 node.
1.3.6.1.4.1.8708.2.29.2.8.1.1.6ColumnauxNodeEventPortread-writecurrentThe event port number for the TM2000 node.
1.3.6.1.4.1.8708.2.29.2.8.1.1.7ColumnauxNodeTimeread-onlycurrentThe date and time of the TM2000 node.
1.3.6.1.4.1.8708.2.29.2.8.1.1.8ColumnauxNodeNtpPrimaryread-writecurrentThe primary NTP Server address. This will default be set to master CU IP address which is 10.0.1.1.
1.3.6.1.4.1.8708.2.29.2.8.1.1.9ColumnauxNodeNtpSecondaryread-writecurrentThe secondary NTP Server address.
1.3.6.1.4.1.8708.2.29.2.8.1.1.10ColumnauxNodeChangeLocalTimeread-writecurrentChange the local date and time. Year - If no century is input the current century is set by default. Month - 1 to 12 Day - 1 to 31 Hour - 0 to 23 Minute - 0 to…
1.3.6.1.4.1.8708.2.29.2.8.1.1.11ColumnauxNodeHostUnreachableread-onlycurrentCan not contact the remote external equipment. Check address and ports. A(ctivation): Contact lost D(e-activation): Contact established again
1.3.6.1.4.1.8708.2.29.2.9NodeauxCabinetList
1.3.6.1.4.1.8708.2.29.2.9.1TableauxCabinetTablenot-accessiblecurrentThe list of Cabinet stuff.
1.3.6.1.4.1.8708.2.29.2.9.1.1RowauxCabinetEntrynot-accessiblecurrentAn entry in the Cabinet list.
1.3.6.1.4.1.8708.2.29.2.9.1.1.1ColumnauxCabinetIndexread-onlycurrentAn arbitrary index assigned to each configuration equipment.
1.3.6.1.4.1.8708.2.29.2.9.1.1.2ColumnauxCabinetNameread-onlycurrentThe name of the cabinet.
1.3.6.1.4.1.8708.2.29.2.9.1.1.3ColumnauxCabinetDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.29.2.9.1.1.4ColumnauxCabinetAdminStatusread-writecurrentThe administrative state of the cabinet. down - The interface is de-activated. service - The interface is activated but alarms are suppressed. Intended for use…
1.3.6.1.4.1.8708.2.29.2.9.1.1.5ColumnauxCabinetOperStatusread-onlycurrentCabinet operational status
1.3.6.1.4.1.8708.2.29.2.9.1.1.6ColumnauxCabinetUpIdread-onlycurrentIdentity in the UP for the auxCabinet entry in the traffic unit
1.3.6.1.4.1.8708.2.29.2.9.1.1.7ColumnauxCabinetIndoorTempread-onlycurrentThe indoor temperature in the cabinet in 0.1 degrees centigrade.
1.3.6.1.4.1.8708.2.29.2.9.1.1.8ColumnauxCabinetOutdoorTempread-onlycurrentThe outdoor temperature in the cabinet in 0.1 degrees centigrade.
1.3.6.1.4.1.8708.2.29.2.9.1.1.9ColumnauxCabinetOperModeread-onlycurrentCabinet operating mode
1.3.6.1.4.1.8708.2.29.2.9.1.1.10ColumnauxCabinetDoorAlarmread-onlycurrentAlarm: The cabinet door is opened. OK: The cabinet door is closed.
1.3.6.1.4.1.8708.2.29.2.9.1.1.11ColumnauxCabinetSPDAlarmread-onlycurrentAlarm: Surge Protection Device alarm. OK: Surge Protection Device ok.
1.3.6.1.4.1.8708.2.29.2.9.1.1.12ColumnauxCabinetHighTempAlarmread-onlycurrentAlarm: Cabinet temperature too high. OK: Cabinet temperature ok.
1.3.6.1.4.1.8708.2.29.2.9.1.1.13ColumnauxCabinetCtrlFailAlarmread-onlycurrentAlarm: Cabinet controller failure. OK: Cabinet controller ok.
1.3.6.1.4.1.8708.2.29.2.9.1.1.14ColumnauxCabinetHeatFailAlarmread-onlycurrentAlarm: Cabinet heater failure. OK: Cabinet heater ok.
1.3.6.1.4.1.8708.2.29.2.9.1.1.15ColumnauxCabinetExtTempFailAlarmread-onlycurrentAlarm: Cabinet external temp sensor failure. OK: Cabinet external temp sensor ok.
1.3.6.1.4.1.8708.2.29.2.9.1.1.16ColumnauxCabinetIntTempFailAlarmread-onlycurrentAlarm: Cabinet internal temp sensor failure. OK: Cabinet internal temp sensor ok.
1.3.6.1.4.1.8708.2.29.2.10NodeauxFanList
1.3.6.1.4.1.8708.2.29.2.10.1TableauxFanTablenot-accessiblecurrentA list of Fans.
1.3.6.1.4.1.8708.2.29.2.10.1.1RowauxFanEntrynot-accessiblecurrentAn entry in the Fan list.
1.3.6.1.4.1.8708.2.29.2.10.1.1.1ColumnauxFanIndexread-onlycurrentAn arbitrary index assigned to each configuration equipment.
1.3.6.1.4.1.8708.2.29.2.10.1.1.2ColumnauxFanNameread-onlycurrentThe name of the fan.
1.3.6.1.4.1.8708.2.29.2.10.1.1.3ColumnauxFanDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.29.2.10.1.1.4ColumnauxFanAdminStatusread-writecurrentThe administrative state of the fan. down - The interface is de-activated. service - The interface is activated but alarms are suppressed. Intended for use dur…
1.3.6.1.4.1.8708.2.29.2.10.1.1.5ColumnauxFanOperStatusread-onlycurrentFan operational status
1.3.6.1.4.1.8708.2.29.2.10.1.1.6ColumnauxFanUpIdread-onlycurrentIdentity in the UP for the auxFan entry in the traffic unit
1.3.6.1.4.1.8708.2.29.2.10.1.1.7ColumnauxFanFailureread-onlycurrentAlarm: The fan has failed. OK: The fan is ok.
1.3.6.1.4.1.8708.2.29.2.10.1.1.8ColumnauxFanRPMread-onlycurrentThe fan RPM.
1.3.6.1.4.1.8708.2.29.2.11NodeauxFanGroupList
1.3.6.1.4.1.8708.2.29.2.11.1TableauxFanGroupTablenot-accessiblecurrentA list of FanGroups.
1.3.6.1.4.1.8708.2.29.2.11.1.1RowauxFanGroupEntrynot-accessiblecurrentAn entry in the FanGroup list.
1.3.6.1.4.1.8708.2.29.2.11.1.1.1ColumnauxFanGroupIndexread-onlycurrentAn arbitrary index assigned to each configuration equipment.
1.3.6.1.4.1.8708.2.29.2.11.1.1.2ColumnauxFanGroupNameread-onlycurrentThe name of the fan group.
1.3.6.1.4.1.8708.2.29.2.11.1.1.3ColumnauxFanGroupDescrread-writecurrentUser configurable label.
1.3.6.1.4.1.8708.2.29.2.11.1.1.4ColumnauxFanGroupAdminStatusread-writecurrentThe administrative state of the fan group. down - The interface is de-activated. service - The interface is activated but alarms are suppressed. Intended for u…
1.3.6.1.4.1.8708.2.29.2.11.1.1.5ColumnauxFanGroupOperStatusread-onlycurrentFanGroup operational status
1.3.6.1.4.1.8708.2.29.2.11.1.1.6ColumnauxFanGroupUpIdread-onlycurrentIdentity in the UP for the auxFanGroup entry in the traffic unit
1.3.6.1.4.1.8708.2.29.2.11.1.1.7ColumnauxFanGroupFailureread-onlycurrentAlarm: The fan group has failed. OK: The fan group is ok.