LUM-SITE-MIB
42 objects
The MIB module for management of customer site properties. The tables contained in this MIB are: (1) The General group contains some general attributes as timestamps and tables sizes. (2) The External Alarm table contains configuration for External Alarm inputs.
Imported Objects
| LUM-ALARM-MIB | AlarmPerceivedSeverity |
| LUM-REG | lumModules lumSiteMIB |
| LUM-TC | AdminStatusWithNA BoardOrInterfaceOperStatus FaultStatus OperStatusWithNA |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DateAndTime DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.8708.1.1.42 | IdentitylumSiteMIBModule | The MIB module for management of customer site properties. The tables contained in this MIB are: (1) The General group contains some general attributes as time… | ||
| 1.3.6.1.4.1.8708.2.42.1 | NodelumSiteConfs | |||
| 1.3.6.1.4.1.8708.2.42.1.1 | NodelumSiteGroups | |||
| 1.3.6.1.4.1.8708.2.42.1.1.1 | GroupsiteGeneralGroupV1 | deprecated | The general objects. | |
| 1.3.6.1.4.1.8708.2.42.1.1.2 | GroupsiteGeneralGroupV2 | current | The general objects. | |
| 1.3.6.1.4.1.8708.2.42.1.1.3 | GroupsiteExtAlarmGroupV1 | deprecated | The External Alarm objects. (18.0) | |
| 1.3.6.1.4.1.8708.2.42.1.1.4 | GroupsiteExtAlarmGroupV2 | current | The External Alarm objects. (28.1) | |
| 1.3.6.1.4.1.8708.2.42.1.1.5 | GroupsiteExtAlarmOutGroupV1 | current | The External Alarm Output objects. (29.0) | |
| 1.3.6.1.4.1.8708.2.42.1.2 | NodelumSiteCompl | |||
| 1.3.6.1.4.1.8708.2.42.1.2.1 | CompliancelumSiteBasicComplV1 | deprecated | Basic implementation requirements for the Site MIB. (R18.0) | |
| 1.3.6.1.4.1.8708.2.42.1.2.2 | CompliancelumSiteBasicComplV2 | deprecated | Basic implementation requirements for the Site MIB. (R28.1) | |
| 1.3.6.1.4.1.8708.2.42.1.2.3 | CompliancelumSiteBasicComplV3 | current | Basic implementation requirements for the Site MIB. (R29.0) | |
| 1.3.6.1.4.1.8708.2.42.2 | NodelumSiteMIBObjects | |||
| 1.3.6.1.4.1.8708.2.42.2.1 | NodesiteGeneral | |||
| 1.3.6.1.4.1.8708.2.42.2.1.1 | ScalarsiteGeneralLastChangeTime | read-only | current | The time when the configuration of the MIB was last changed. |
| 1.3.6.1.4.1.8708.2.42.2.1.2 | ScalarsiteGeneralStateLastChangeTime | read-only | current | The time when the state of the MIB was last changed. |
| 1.3.6.1.4.1.8708.2.42.2.1.3 | ScalarsiteGeneralExtAlarmTableSize | read-only | current | Number of entries in External Alarms table |
| 1.3.6.1.4.1.8708.2.42.2.1.4 | ScalarsiteGeneralExtAlarmOutTableSize | read-only | current | Number of entries in External Alarms output table |
| 1.3.6.1.4.1.8708.2.42.2.2 | NodesiteExtAlarmList | |||
| 1.3.6.1.4.1.8708.2.42.2.2.1 | TablesiteExtAlarmTable | not-accessible | current | This table handles configuration and alarm status for all External Alarms in the system. One entry in this table represents a single External Alarm logical inp… |
| 1.3.6.1.4.1.8708.2.42.2.2.1.1 | RowsiteExtAlarmEntry | not-accessible | current | An entry in the External Alarm table. Each entry represents a logical External Alarm input. |
| 1.3.6.1.4.1.8708.2.42.2.2.1.1.1 | ColumnsiteExtAlarmIndex | read-only | current | An arbitrary index assigned to each External Alarm entry. |
| 1.3.6.1.4.1.8708.2.42.2.2.1.1.2 | ColumnsiteExtAlarmName | read-only | current | The name of the External Alarm, e.g. 'extalarm:1:1:2'. The first number indicates the subrack where the physical External Alarm connector is located. The secon… |
| 1.3.6.1.4.1.8708.2.42.2.2.1.1.3 | ColumnsiteExtAlarmAdminStatus | read-write | current | The administrative state of the External Alarm. down - The external alarm is not in use. Suppresses alarm propagation. up - The external alarm is in use. |
| 1.3.6.1.4.1.8708.2.42.2.2.1.1.4 | ColumnsiteExtAlarmLevel | read-write | current | 'Active' level of this alarm: activeHigh Alarm is activated by a high input signal level. activeLow Alarm is activated by a low input signal level. |
| 1.3.6.1.4.1.8708.2.42.2.2.1.1.5 | ColumnsiteExtAlarmSeverity | read-write | current | The severity of this alarm. |
| 1.3.6.1.4.1.8708.2.42.2.2.1.1.6 | ColumnsiteExtAlarmText | read-write | current | The alarm text associated with this alarm. The alarm text is displayed in alarm lists and logs. |
| 1.3.6.1.4.1.8708.2.42.2.2.1.1.7 | ColumnsiteExtAlarmActive | read-only | current | The external alarm is active according to active high or low setting configured by the 'Level' attribute. Activation: Active HW indication. De-activation: Inac… |
| 1.3.6.1.4.1.8708.2.42.2.2.1.1.8 | ColumnsiteExtAlarmId | read-only | current | Identifier for the entry |
| 1.3.6.1.4.1.8708.2.42.2.2.1.1.9 | ColumnsiteExtAlarmOperStatus | read-only | current | The operational state of the external alarm. This attribute is required to automatically suppress (or not) alarmActive from admin status attribute. |
| 1.3.6.1.4.1.8708.2.42.2.3 | NodesiteExtAlarmOutList | |||
| 1.3.6.1.4.1.8708.2.42.2.3.1 | TablesiteExtAlarmOutTable | not-accessible | current | This table handles configuration and alarm status for all Output External Alarms in the system. One entry in this table represents a single External Alarm logi… |
| 1.3.6.1.4.1.8708.2.42.2.3.1.1 | RowsiteExtAlarmOutEntry | not-accessible | current | An entry in the External Alarm Output table. Each entry represents a logical External Alarm output. |
| 1.3.6.1.4.1.8708.2.42.2.3.1.1.1 | ColumnsiteExtAlarmOutIndex | read-only | current | An arbitrary index assigned to each External Alarm output entry. |
| 1.3.6.1.4.1.8708.2.42.2.3.1.1.2 | ColumnsiteExtAlarmOutName | read-only | current | The name of the External Alarm Output, e.g. 'extalarmout:1:1:2'. The first number indicates the subrack where the physical External Alarm Output connector is l… |
| 1.3.6.1.4.1.8708.2.42.2.3.1.1.3 | ColumnsiteExtAlarmOutAdminStatus | read-write | current | The administrative state of the External Alarm Output. down - The external alarm output is not in use. Suppresses alarm propagation. up - The external alarm is… |
| 1.3.6.1.4.1.8708.2.42.2.3.1.1.4 | ColumnsiteExtAlarmOutOperStatus | read-only | current | The operational state of the external alarm output. This attribute is required to automatically suppress (or not) alarmActive from admin status attribute. |
| 1.3.6.1.4.1.8708.2.42.2.3.1.1.5 | ColumnsiteExtAlarmOutLevel | read-write | current | 'Active' level of this alarm: activeHigh Alarm is activated by a high input signal level. activeLow Alarm is activated by a low input signal level. |
| 1.3.6.1.4.1.8708.2.42.2.3.1.1.6 | ColumnsiteExtAlarmOutSeverity | read-write | current | The severity of this alarm. |
| 1.3.6.1.4.1.8708.2.42.2.3.1.1.7 | ColumnsiteExtAlarmOutText | read-write | current | The alarm text associated with this alarm. |
| 1.3.6.1.4.1.8708.2.42.2.3.1.1.8 | ColumnsiteExtAlarmOutActive | read-only | current | The external alarm output is active according to active high or low setting configured by the 'Level' attribute. Activation: Active HW indication. De-activatio… |
| 1.3.6.1.4.1.8708.2.42.2.3.1.1.9 | ColumnsiteExtAlarmOutId | read-only | current | Identifier for the entry |