OMNI-gx2CEB-MIB
119 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.20.1 | Nodegx2CEBDescriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.20.1 | NodetrapCEBConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.20.2 | Tablegx2CEBAnalogTable | not-accessible | mandatory | This table contains gx2CEB specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.20.2 | NodetrapCEBConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.20.2.1 | Rowgx2CEBAnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.1 | Columngx2CEBAnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.2 | ColumnceblabelModTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.3 | ColumncebuomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.4 | ColumncebmajorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.5 | ColumncebmajorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.6 | ColumncebminorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.7 | ColumncebminorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.8 | ColumncebcurrentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.9 | ColumncebstateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.10 | ColumncebminValueModTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.11 | ColumncebmaxValueModTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.12 | ColumncebalarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.13 | ColumnceblabelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.14 | ColumncebuomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.15 | ColumncebmajorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.16 | ColumncebmajorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.17 | ColumncebminorHighFanCurrent | read-only | obsolete | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.18 | ColumncebminorLowFanCurrent | read-only | obsolete | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.19 | ColumncebcurrentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.20 | ColumncebstateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.21 | ColumncebminValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.22 | ColumncebmaxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.23 | ColumncebalarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.24 | ColumnceblabelAnalogVoltage01 | read-only | optional | The value of this object provides the label of the Analog Voltage number 01 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.25 | ColumncebuomAnalogVoltage01 | read-only | optional | The value of this object provides the Unit of Measure of the Analog Voltage number 01 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.26 | ColumncebmajorHighAnalogVoltage01 | read-only | mandatory | The value of this object provides the Major High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.27 | ColumncebmajorLowAnalogVoltage01 | read-only | mandatory | The value of this object provides the Major Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.28 | ColumncebminorHighAnalogVoltage01 | read-only | mandatory | The value of this object provides the Minor High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.29 | ColumncebminorLowAnalogVoltage01 | read-only | mandatory | The value of this object provides the Minor Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.30 | ColumncebcurrentValueAnalogVoltage01 | read-only | mandatory | The value of this object provides the Current value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.31 | ColumncebstateFlagAnalogVoltage01 | read-only | mandatory | The value of this object provides the state of the Analog Voltage number 01 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.32 | ColumncebminValueAnalogVoltage01 | read-only | mandatory | The value of this object provides the minimum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.33 | ColumncebmaxValueAnalogVoltage01 | read-only | mandatory | The value of this object provides the maximum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.34 | ColumncebalarmStateAnalogVoltage01 | read-only | mandatory | The value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.35 | ColumnceblabelAnalogVoltage02 | read-only | optional | The value of this object provides the label of the Analog Voltage number 02 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.36 | ColumncebuomAnalogVoltage02 | read-only | optional | The value of this object provides the Unit of Measure of the Analog Voltage number 02 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.37 | ColumncebmajorHighAnalogVoltage02 | read-only | mandatory | The value of this object provides the Major High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.38 | ColumncebmajorLowAnalogVoltage02 | read-only | mandatory | The value of this object provides the Major Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.39 | ColumncebminorHighAnalogVoltage02 | read-only | mandatory | The value of this object provides the Minor High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.40 | ColumncebminorLowAnalogVoltage02 | read-only | mandatory | The value of this object provides the Minor Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.41 | ColumncebcurrentValueAnalogVoltage02 | read-only | mandatory | The value of this object provides the Current value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.42 | ColumncebstateFlagAnalogVoltage02 | read-only | mandatory | The value of this object provides the state of the Analog Voltage number 02 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.43 | ColumncebminValueAnalogVoltage02 | read-only | mandatory | The value of this object provides the minimum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.44 | ColumncebmaxValueAnalogVoltage02 | read-only | mandatory | The value of this object provides the maximum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.45 | ColumncebalarmStateAnalogVoltage02 | read-only | mandatory | The value of this object provides the curent alarm state of the Analog Voltage number 02 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.46 | ColumnceblabelAnalogVoltage03 | read-only | optional | The value of this object provides the label of the Analog Voltage number 03 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.47 | ColumncebuomAnalogVoltage03 | read-only | optional | The value of this object provides the Unit of Measure of the Analog Voltage number 03 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.48 | ColumncebmajorHighAnalogVoltage03 | read-only | mandatory | The value of this object provides the Major High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.49 | ColumncebmajorLowAnalogVoltage03 | read-only | mandatory | The value of this object provides the Major Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.50 | ColumncebminorHighAnalogVoltage03 | read-only | mandatory | The value of this object provides the Minor High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.51 | ColumncebminorLowAnalogVoltage03 | read-only | mandatory | The value of this object provides the Minor Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.52 | ColumncebcurrentValueAnalogVoltage03 | read-only | mandatory | The value of this object provides the Current value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.53 | ColumncebstateFlagAnalogVoltage03 | read-only | mandatory | The value of this object provides the state of the Analog Voltage number 03 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.54 | ColumncebminValueAnalogVoltage03 | read-only | mandatory | The value of this object provides the minimum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.55 | ColumncebmaxValueAnalogVoltage03 | read-only | mandatory | The value of this object provides the maximum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.56 | ColumncebalarmStateAnalogVoltage03 | read-only | mandatory | The value of this object provides the curent alarm state of the Analog Voltage number 03 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.57 | ColumnceblabelAnalogVoltage04 | read-only | optional | The value of this object provides the label of the Analog Voltage number 04 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.58 | ColumncebuomAnalogVoltage04 | read-only | optional | The value of this object provides the Unit of Measure of the Analog Voltage number 04 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.59 | ColumncebmajorHighAnalogVoltage04 | read-only | mandatory | The value of this object provides the Major High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.60 | ColumncebmajorLowAnalogVoltage04 | read-only | mandatory | The value of this object provides the Major Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.61 | ColumncebminorHighAnalogVoltage04 | read-only | mandatory | The value of this object provides the Minor High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.62 | ColumncebminorLowAnalogVoltage04 | read-only | mandatory | The value of this object provides the Minor Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.63 | ColumncebcurrentValueAnalogVoltage04 | read-only | mandatory | The value of this object provides the Current value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.64 | ColumncebstateFlagAnalogVoltage04 | read-only | mandatory | The value of this object provides the state of the Analog Voltage number 04 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.65 | ColumncebminValueAnalogVoltage04 | read-only | mandatory | The value of this object provides the minimum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.66 | ColumncebmaxValueAnalogVoltage04 | read-only | mandatory | The value of this object provides the maximum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.67 | ColumncebalarmStateAnalogVoltage04 | read-only | mandatory | The value of this object provides the curent alarm state of the Analog Voltage number 04 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.68 | ColumnceblabelAnalogVoltage05 | read-only | optional | The value of this object provides the label of the Analog Voltage number 05 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.69 | ColumncebuomAnalogVoltage05 | read-only | optional | The value of this object provides the Unit of Measure of the Analog Voltage number 05 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.70 | ColumncebmajorHighAnalogVoltage05 | read-only | mandatory | The value of this object provides the Major High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.71 | ColumncebmajorLowAnalogVoltage05 | read-only | mandatory | The value of this object provides the Major Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.72 | ColumncebminorHighAnalogVoltage05 | read-only | mandatory | The value of this object provides the Minor High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.73 | ColumncebminorLowAnalogVoltage05 | read-only | mandatory | The value of this object provides the Minor Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.74 | ColumncebcurrentValueAnalogVoltage05 | read-only | mandatory | The value of this object provides the Current value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.75 | ColumncebstateFlagAnalogVoltage05 | read-only | mandatory | The value of this object provides the state of the Analog Voltage number 05 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.76 | ColumncebminValueAnalogVoltage05 | read-only | mandatory | The value of this object provides the minimum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.77 | ColumncebmaxValueAnalogVoltage05 | read-only | mandatory | The value of this object provides the maximum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is rep… |
| 1.3.6.1.4.1.1166.6.1.2.20.2.1.78 | ColumncebalarmStateAnalogVoltage05 | read-only | mandatory | The value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.3 | Tablegx2CEBStatusTable | not-accessible | mandatory | This table contains gx2CEB specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.20.3 | NodetrapCEBfanCurrentAlarm | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.20.3.2 | Rowgx2CEBStatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.1 | Columngx2CEBStatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.2 | ColumnceblabelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.3 | ColumncebvalueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.4 | ColumncebstateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.5 | ColumnceblabelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.6 | ColumncebvalueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.7 | ColumncebstateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.8 | ColumnceblabelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.9 | ColumncebvalueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.10 | ColumncebstateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.11 | ColumnceblabelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.12 | ColumncebvalueAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.20.3.2.13 | ColumncebstateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.20.4 | Tablegx2CEBFactoryTable | not-accessible | mandatory | This table contains gx2CEB specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.20.4 | NodetrapCEBModuleTempAlarm | This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.20.4.3 | Rowgx2CEBFactoryEntry | not-accessible | mandatory | This list contains Factory parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.1 | Columngx2CEBFactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.2 | ColumncebbootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.3 | ColumncebbootStatusByte | read-only | mandatory | This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 =… |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.4 | Columncebbank1CRC | read-only | mandatory | This object provides the CRC code of bank 0. The display formate for the data is Hex. |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.5 | Columncebbank2CRC | read-only | mandatory | This object provides the CRC code of bank 1.The display formate for the data is Hex. |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.6 | ColumncebprgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.7 | ColumncebfactoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.8 | ColumncebcalculateCRC | read-only | obsolete | This object indicates which of the Enums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.9 | ColumncebhourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.10 | ColumncebflashPrgCntA | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.11 | ColumncebflashPrgCntB | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.12 | ColumncebflashBankARev | read-only | mandatory | This object provides the revision of flash bank 0. The rev is 2 characters. |
| 1.3.6.1.4.1.1166.6.1.2.20.4.3.13 | ColumncebflashBankBRev | read-only | mandatory | This object provides the revision of flash bank 1. The rev is 2 characters. |
| 1.3.6.1.4.1.1166.6.1.2.20.5 | NodetrapCEBFlashAlarm | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.20.6 | NodetrapCEBBankBootAlarm | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.20.7 | NodetrapCEBAlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.20.8 | NodetrapCEBFactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. |