OMNI-gx2CM-MIB
275 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.3.1 | Nodegx2cmDescriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.3.1 | NodetrapCMConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.3.2 | Tablegx2cmFactoryTable | not-accessible | mandatory | This table contains gx2Cm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.3.2 | NodetrapCMConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.3.2.1 | Rowgx2cmFactoryEntry | not-accessible | mandatory | This list contains Factory data and the associated parameter descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.1 | Columngx2cmFactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.2 | ColumnbootControlByte | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.3 | ColumnbootStatusByte | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.4 | Columnbank0CRC | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.5 | Columnbank1CRC | read-only | mandatory | This object provides the CRC code of bank 2. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.6 | ColumnprgEEPROMByte | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.7 | ColumnfactoryCRC | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.8 | ColumncalculateCRC | read-only | mandatory | This object provides the CRC value of the fimware. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.9 | ColumnhourMeter | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.10 | ColumnflashPrgCnt0 | read-only | mandatory | This object provides the number of times the flash has been programmed on side A. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.11 | ColumnflashPrgCnt1 | read-only | mandatory | This object provides the number of times the flash has been programmed on side B. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.12 | ColumnflashBank0 | read-only | mandatory | This object provides the firmware revision of the firmware in bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.13 | ColumnflashBank1 | read-only | mandatory | This object provides the firmware revision of the firmware in bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.14 | ColumnlocalMacAdd | read-only | mandatory | This object provides the local mac address number |
| 1.3.6.1.4.1.1166.6.1.2.3.2.1.15 | ColumnnetWorkMacAdd | read-only | mandatory | This object provides the network mac address number. |
| 1.3.6.1.4.1.1166.6.1.2.3.3 | Tablegx2cmNetworkTable | not-accessible | mandatory | This table contains gx2Cm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.3.3 | NodetrapCMModuleTempAlarm | This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.3.3.2 | Rowgx2cmNetworkEntry | not-accessible | mandatory | This list contains Network parameters and the associated parameter descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.1 | Columngx2cmNetworkTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.2 | ColumnlabelLocalEthIPAdd | read-only | optional | This object provides the label for the Ethernet IP Address field. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.3 | ColumnvalueLocalEthIPAdd | read-write | mandatory | This object provides the Local Ethernet IP Address for the Control Module. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.4 | ColumnlabelLocalEthMask | read-only | optional | This object provides the label for the Local Ethernet Mask field. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.5 | ColumnvalueLocalEthMask | read-write | mandatory | This object provides the Local Ethernet Mask value. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.6 | ColumnlabelNetworkEthAdd | read-only | optional | This object provides the label for the Network Ethernet Address . |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.7 | ColumnvalueNetworkEthAdd | read-write | mandatory | This object provides the value of the Network Ethernet Address. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.8 | ColumnlabelNetworkEthMask | read-only | optional | This object provides the label for the Network Mask Address. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.9 | ColumnvalueNetworkEthMask | read-write | mandatory | This object provides the value of the Network Mask Address. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.10 | ColumnlabelShelfSerialNum | read-only | optional | This object provides the label for the Shelf Serial Number. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.11 | ColumnvalueShelfSerialNum | read-only | mandatory | This object provides the value for the Shelf Serial Number. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.12 | ColumnlabelGateWayIPAdd | read-only | optional | This object provides the label for the Gateway IP address. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.13 | ColumnvalueGateWayIPAdd | read-write | mandatory | This object provides the value for the IP address for the Gateway. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.14 | ColumnlabelTrapDestination | read-only | optional | This object provides the label the trap destination field. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.15 | ColumnvalueTrapDestination | read-write | mandatory | This object provides the address for the trap destination. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.16 | ColumnlabelTFTPserver | read-only | optional | This object provides the label the TFTP Server address field. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.17 | ColumnvalueTFTPserver | read-write | mandatory | This object provides the address for the TFTP Server. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.18 | ColumnlabelTrap2Destination | read-only | optional | This object provides the label the second trap destination field. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.19 | ColumnvalueTrap2Destination | read-write | mandatory | This object provides the address for the second trap destination. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.20 | ColumnlabelTrap3Destination | read-only | optional | This object provides the label the third trap destination field. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.21 | ColumnvalueTrap3Destination | read-write | mandatory | This object provides the address for the third trap destination. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.22 | ColumnlabelTrap4Destination | read-only | optional | This object provides the label the fourth trap destination field. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.23 | ColumnvalueTrap4Destination | read-write | mandatory | This object provides the address for the fourth trap destination. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.24 | ColumnlabelTrap5Destination | read-only | optional | This object provides the label the fifth trap destination field. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.25 | ColumnvalueTrap5Destination | read-write | mandatory | This object provides the address for the fifth trap destination. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.26 | ColumnlabelISDNMode | read-only | optional | This object provides the label for the ISDN mode setting. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.27 | ColumnvalueISDNMode | read-write | mandatory | This object provides the value for the ISDN mode setting. In order to activate the ISDN feature, the user must set the ISDN mode to ON and provide a valid IP a… |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.28 | ColumnlabelISDNModemIPAddress | read-only | optional | This object provides the label for the ISDN modem IP Address. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.29 | ColumnvalueISDNModemIPAddress | read-write | mandatory | This object provides the value for the ISDN modem IP Address. This Address is used by the control Module to ping the remote ISDN modem to determine if an ISDN … |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.30 | ColumnlabelISDNTrapTimeout | read-only | optional | This object provides the label for the ISDN modem Timeout object. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.31 | ColumnvalueISDNTrapTimeout | read-write | mandatory | This object provides the value for the ISDN modem Timeout. The value of this object sets the time period that the communication link is open for sending traps.… |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.32 | ColumnlabelISDNPingTimeout | read-only | optional | This object provides the label for the ISDN ping timeout object. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.33 | ColumnvalueISDNPingTimeout | read-write | mandatory | This object provides the value for the ISDN ping timeout. Factory default value is 500 ms. User should set this value in milli-second |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.34 | ColumnlabelISDNBackoffTimer | read-only | optional | This object provides the label for the ISDN backoff timer object. |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.35 | ColumnvalueISDNBackoffTimer | read-write | mandatory | This object provides the value for the ISDN backoff timer. The value in this object is a hold period used to prevent traps from being sent. It is used to allow… |
| 1.3.6.1.4.1.1166.6.1.2.3.4 | Tablegx2cmAnalogTable | not-accessible | mandatory | This table contains gx2Cm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.3.4 | NodetrapCMEEPROMAlarm | This trap is issued when the EEPROM detectes an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.3.4.3 | Rowgx2cmAnalogEntry | not-accessible | mandatory | This list contains analog parameters and the associated parameter descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.1 | Columngx2cmTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.2 | ColumnlabelModTemp | read-only | optional | The value of this object provides the label of the Module Temp parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.3 | ColumnuomModTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temp parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.4 | ColumnmajorHighModTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temp parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.5 | ColumnmajorLowModTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temp parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.6 | ColumnminorHighModTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temp parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.7 | ColumnminorLowModTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temp parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.8 | ColumncurrentValueModTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temp parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.9 | ColumnstateFlagModTemp | read-only | mandatory | The value of this object provides the state of the Module Temp parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.10 | ColumnminValueModTemp | read-only | optional | The value of this object provides the minimum value the Module Temp parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.11 | ColumnmaxValueModTemp | read-only | optional | The value of this object provides the maximum value the Module Temp parameter can achive. |
| 1.3.6.1.4.1.1166.6.1.2.3.4.3.12 | ColumnalarmStateModTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temp Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.5 | Tablegx2cmDigitalTable | not-accessible | mandatory | This table contains gx2Cm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.3.5 | NodetrapCMFlashAlarm | This trap is issued when the Flash device detects an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.3.5.4 | Rowgx2cmDigitalEntry | not-accessible | mandatory | This list contains digital parameters and the associated parameter descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.1 | Columngx2cmDigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.2 | ColumnlabelRemoteLocal | read-only | obsolete | The value of this object provides the label of the Remote Local Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.3 | ColumnenumRemoteLocal | read-only | obsolete | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value … |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.4 | ColumnvalueRemoteLocal | read-write | obsolete | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.5 | ColumnstateFlagRemoteLocal | read-only | obsolete | The value of this object provides the state of the Remote Local Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.6 | ColumnlabelResetSlot | read-only | optional | The value of this object provides the label of the Reset Slot Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.7 | ColumnenumResetSlot | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value … |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.8 | ColumnvalueResetSlot | read-write | mandatory | The value of this object is the current value of the parameter. A write to this object will casue a hardware reset. 0-control module 1-18 selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.9 | ColumnstateResetSlot | read-only | mandatory | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.10 | ColumnlabelIdShelf | read-only | optional | The value of this object provides the label of the identify shelf Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.11 | ColumnenumIdShelf | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value … |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.12 | ColumnvalueIdShelf | read-write | mandatory | The value of this object is the current value of the parameter. Writing any non zero value to this parameter will casue the CM to blink its front panel LED. |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.13 | ColumnstateFlagIdShelf | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.14 | ColumnlabelResetAlarm | read-only | optional | The value of this object provides the label of the Reset Alarms Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.15 | ColumnenumResetAlarm | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value … |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.16 | ColumnvalueResetAlarm | read-write | mandatory | The value of this object is the current value of the parameter. Writing any non-zero value to this object will case the CM to reset shelf alarm processing. |
| 1.3.6.1.4.1.1166.6.1.2.3.5.4.17 | ColumnstateFlagResetAlarm | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.3.6 | Tablegx2cmStatusTable | not-accessible | mandatory | This table contains gx2Cm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.3.6 | NodetrapCMHardwareAlarm | This trap is issued when the system hardware detectes an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.3.6.5 | Rowgx2cmStatusEntry | not-accessible | mandatory | This list contains status parameters and the associated parameter descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.1 | Columngx2cmStatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.2 | ColumnlabelShelfAlarm | read-only | optional | The value of this object provides the label of the Shelf Alarm Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.3 | ColumnvalueShelfAlarm | read-only | mandatory | The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.4 | ColumnstateShelfAlarm | read-only | mandatory | The value of this object provides the current state of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.5 | ColumnlabelDataCrc | read-only | optional | The value of this object provides the label of the Data CRC parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.6 | ColumnvalueDataCrc | read-only | mandatory | The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.7 | ColumnstateDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.8 | ColumnlabelFlashStatus | read-only | optional | The value of this object provides the label of the Flash Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.9 | ColumnvalueFlashStatus | read-only | mandatory | The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.10 | ColumnstateFlashStatus | read-only | mandatory | The value of this object provides the current state of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.11 | ColumnlabelBootStatus | read-only | optional | The value of this object provides the label of the Boot Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.12 | ColumnvalueBootStatus | read-only | mandatory | The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.13 | ColumnstateBootStatus | read-only | mandatory | The value of this object provides the current state of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.14 | ColumnlabelAlmLimCrc | read-only | optional | The value of this object provides the label of the Alarm limit CRC parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.15 | ColumnvalueAlmLimCrc | read-only | mandatory | The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.3.6.5.16 | ColumnstateAlmLimCrc | read-only | mandatory | The value of this object provides the current state of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.3.7 | Tablegx2cmAMCTable | not-accessible | mandatory | This table contains gx2Cm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.3.7 | NodetrapCMInitEEPROMAlarm | This trap is issued when the there is an EEPROM initializing error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.3.7.6 | Rowgx2cmAMCEntry | not-accessible | mandatory | This list contains the AMC parameters and the associated parameter descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.1 | Columngx2cmAMCTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.2 | ColumnvalueAMCslot1 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.3 | ColumnserialAMCslot1 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.4 | ColumnagentIDAMCslot1 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.5 | ColumnvalueAMCslot2 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.6 | ColumnserialAMCslot2 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.7 | ColumnagentIDAMCslot2 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.8 | ColumnvalueAMCslot3 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.9 | ColumnserialAMCslot3 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.10 | ColumnagentIDAMCslot3 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.11 | ColumnvalueAMCslot4 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.12 | ColumnserialAMCslot4 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.13 | ColumnagentIDAMCslot4 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.14 | ColumnvalueAMCslot5 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.15 | ColumnserialAMCslot5 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.16 | ColumnagentIDAMCslot5 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.17 | ColumnvalueAMCslot6 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.18 | ColumnserialAMCslot6 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.19 | ColumnagentIDAMCslot6 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.20 | ColumnvalueAMCslot7 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.21 | ColumnserialAMCslot7 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.22 | ColumnagentIDAMCslot7 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.23 | ColumnvalueAMCslot8 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.24 | ColumnserialAMCslot8 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.25 | ColumnagentIDAMCslot8 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.26 | ColumnvalueAMCslot9 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.27 | ColumnserialAMCslot9 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.28 | ColumnagentIDAMCslot9 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.29 | ColumnvalueAMCslot10 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.30 | ColumnserialAMCslot10 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.31 | ColumnagentIDAMCslot10 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.32 | ColumnvalueAMCslot11 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.33 | ColumnserialAMCslot11 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.34 | ColumnagentIDAMCslot11 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.35 | ColumnvalueAMCslot12 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.36 | ColumnserialAMCslot12 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.37 | ColumnagentIDAMCslot12 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.38 | ColumnvalueAMCslot13 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.39 | ColumnserialAMCslot13 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.40 | ColumnagentIDAMCslot13 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.41 | ColumnvalueAMCslot14 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.42 | ColumnserialAMCslot14 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.43 | ColumnagentIDAMCslot14 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.44 | ColumnvalueAMCslot15 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.45 | ColumnserialAMCslot15 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.46 | ColumnagentIDAMCslot15 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.47 | ColumnvalueAMCslot16 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.48 | ColumnserialAMCslot16 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.49 | ColumnagentIDAMCslot16 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.50 | ColumnvalueAMCslot17 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.51 | ColumnserialAMCslot17 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.52 | ColumnagentIDAMCslot17 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.53 | ColumnvalueAMCslot18 | read-write | mandatory | This object provides control to enable or disable AMC for the current device in the slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.54 | ColumnserialAMCslot18 | read-only | mandatory | This object provides the serial number for the AMC slot selected. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.55 | ColumnagentIDAMCslot18 | read-only | mandatory | This object provides the agentID of the AMC parameter for the selected slot. |
| 1.3.6.1.4.1.1166.6.1.2.3.7.6.56 | ColumnautoQuickSwapCnt | read-write | mandatory | This object sets the time interval as to when the Control Module will update its memory with quick swap data. The Control Module will enable the quick swap fea… |
| 1.3.6.1.4.1.1166.6.1.2.3.8 | Tablegx2cmSecurityTable | not-accessible | mandatory | This table contains gx2Cm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.3.8 | NodetrapCMBootAlarm | This trap is issued when the there is a boot error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.3.8.7 | Rowgx2cmSecurityEntry | not-accessible | mandatory | This list contains Security parameters and the associated parameter descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.1 | Columngx2cmSecurityTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.2 | ColumnlabelSecurityMode | read-only | optional | This object provides the label for the Current Security Mode. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.3 | ColumnenumSecurityMode | read-only | optional | The value of this object represents the Enumeration values possible for the security mode parameter. Each Enumerated value is separated by a common. The first … |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.4 | ColumnvalueSecurityMode | read-only | mandatory | This object indicates the current Security Mode. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.5 | ColumnstateSecurityMode | read-only | mandatory | This object indicates the state of the Security Mode parameter . |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.6 | ColumnlabelPassword | read-only | optional | This object provides the label for the Password field. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.7 | ColumnvaluePassword | read-write | mandatory | This object provides the value for the Password. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.8 | ColumnstatePassword | read-only | mandatory | This object provides the state of the password field. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.9 | ColumnlabelFactoryChgString | read-only | optional | This object provides the lable for the Factory Change String field. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.10 | ColumnvalueFactoryChgString | write-only | mandatory | This object provides the value for the Factory Change String. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.11 | ColumnstateFactoryChgString | read-only | mandatory | This object provides the state of the Factory Change String field. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.12 | ColumnlabelOperatorChgString | read-only | optional | This object provides the lable for the Operator Change String field. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.13 | ColumnvalueOperatorChgString | write-only | mandatory | This object provides the value for the Operator Change String. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.14 | ColumnstateOperatorChgString | read-only | mandatory | This object provides the state of the Operator Change String field. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.15 | ColumnlabelReadOnlyChgString | read-only | optional | This object provides the lable for the Read Only Change String field. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.16 | ColumnvalueReadOnlyChgString | write-only | mandatory | This object provides the value for the Read Only Change String. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.17 | ColumnstateReadOnlyChgString | read-only | mandatory | This object provides the state of the Read Only Change String field. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.18 | ColumnlabelRemoteOnlyChgString | read-only | optional | This object provides the lable for the Remote Only Change String field. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.19 | ColumnvalueRemoteOnlyChgString | write-only | mandatory | This object provides the value for the Remote Only Change String. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.20 | ColumnstateRemoteOnlyChgString | read-only | mandatory | This object provides the state of the Remote Only Change String field. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.21 | ColumnlabelLocalOnlyChgString | read-only | optional | This object provides the lable for the Local Only Change String field. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.22 | ColumnvalueLocalOnlyChgString | write-only | mandatory | This object provides the value for the Local Only Change String. |
| 1.3.6.1.4.1.1166.6.1.2.3.8.7.23 | ColumnstateLocalOnlyChgString | read-only | mandatory | This object provides the state of the Local Only Change String field. |
| 1.3.6.1.4.1.1166.6.1.2.3.9 | Tablegx2cmDiagnosticTable | not-accessible | mandatory | This table contains gx2Cm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8 | Rowgx2cmDiagnosticEntry | not-accessible | mandatory | This list contains Diagnostic parameters and the associated parameter descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.1 | Columngx2cmDiagnosticTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.2 | ColumnledTestValue | read-write | mandatory | This object provides the LED test pattern on/off control. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.3 | ColumnbpTestCnt | read-write | mandatory | The value of this object control which slot the alarm poll command will be repeatedly sent to. During this operation normal polling is disabled. 0-off, 1-18 se… |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.4 | ColumnsuccessTransSlot1 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.5 | ColumnsuccessTransSlot2 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.6 | ColumnsuccessTransSlot3 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.7 | ColumnsuccessTransSlot4 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.8 | ColumnsuccessTransSlot5 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.9 | ColumnsuccessTransSlot6 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.10 | ColumnsuccessTransSlot7 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.11 | ColumnsuccessTransSlot8 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.12 | ColumnsuccessTransSlot9 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.13 | ColumnsuccessTransSlot10 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.14 | ColumnsuccessTransSlot11 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.15 | ColumnsuccessTransSlot12 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.16 | ColumnsuccessTransSlot13 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.17 | ColumnsuccessTransSlot14 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.18 | ColumnsuccessTransSlot15 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.19 | ColumnsuccessTransSlot16 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.20 | ColumnsuccessTransSlot17 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.21 | ColumnsuccessTransSlot18 | read-write | mandatory | This object provides data on the number of time writing to the selected slot passes. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.22 | ColumnfailureTransSlot1 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.23 | ColumnfailureTransSlot2 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.24 | ColumnfailureTransSlot3 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.25 | ColumnfailureTransSlot4 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.26 | ColumnfailureTransSlot5 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.27 | ColumnfailureTransSlot6 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.28 | ColumnfailureTransSlot7 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.29 | ColumnfailureTransSlot8 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.30 | ColumnfailureTransSlot9 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.31 | ColumnfailureTransSlot10 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.32 | ColumnfailureTransSlot11 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.33 | ColumnfailureTransSlot12 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.34 | ColumnfailureTransSlot13 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.35 | ColumnfailureTransSlot14 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.36 | ColumnfailureTransSlot15 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.37 | ColumnfailureTransSlot16 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.38 | ColumnfailureTransSlot17 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.39 | ColumnfailureTransSlot18 | read-write | mandatory | This object provides data on the number of time writing to the selected slot fails. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.40 | ColumnfanTestMode | read-write | mandatory | This object provides control for putting the fan in manual test mode. Writing any non-zero value will set to on |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.41 | ColumnfanControl | read-write | mandatory | This object provides control over the fan mode. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.42 | ColumnrelayTestMode | read-write | mandatory | This object provides control for putting the relay in manual test mode. Writing any non-zero value will set to on |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.43 | ColumnrelayControl | read-write | mandatory | This object provides control for putting the relay in manual test mode. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.44 | ColumnslotPollMode | read-write | mandatory | This object provides control of the slotpoll test mode. When on the slotpoll operation is disabled. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.45 | ColumnbootCount | read-write | mandatory | This object provides the value of how many times the CM went though a boot/rest process. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.46 | ColumnobjectTableData | read-only | mandatory | This object provides the OID for the start loations for the status, digital and analog tables. This data is used by the web server application. |
| 1.3.6.1.4.1.1166.6.1.2.3.9.8.47 | ColumnsetSysTime | read-write | mandatory | Writing any value to this object will reset sysUpTime to zero. |
| 1.3.6.1.4.1.1166.6.1.2.3.10 | Tablegx2cmDownloadTable | not-accessible | mandatory | This table contains gx2Cm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.3.10.9 | Rowgx2cmDownloadEntry | not-accessible | mandatory | This list contains Download parameters and the associated parameter descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.3.10.9.1 | Columngx2cmDownloadTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.3.10.9.2 | ColumndownloadValue | read-write | mandatory | This object provides the slot(s) to be downloaded. The slots to be downloaded corresponds to the following bit map. bit 0 - control module, bits 1-18 to the co… |
| 1.3.6.1.4.1.1166.6.1.2.3.10.9.3 | ColumnautoDownloadReset | read-write | mandatory | This object determines if the module will be reset directly after a successfull download. 0 - Deactivated, 1+ Activated |
| 1.3.6.1.4.1.1166.6.1.2.3.10.9.4 | ColumndownloadFilename | read-write | mandatory | This object provides the name of the file for download |
| 1.3.6.1.4.1.1166.6.1.2.3.10.9.5 | ColumndownloadState | read-write | mandatory | This object provides the current state of the download process. |
| 1.3.6.1.4.1.1166.6.1.2.3.10.9.6 | ColumnswitchFwBank | read-write | mandatory | Writting to this object causes the firmware bank to switch and execute from that bank. The range of values that can be entered for this object is from 0 to 18.… |
| 1.3.6.1.4.1.1166.6.1.2.3.11 | TablecmTrapHistoryTable | not-accessible | mandatory | This table contains the trap specific parameters. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10 | RowcmTrapHistoryEntry | not-accessible | mandatory | This list contains Trap History parameters and the associated parameter descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.1 | ColumncmTrapHistoryTableIndex | read-only | mandatory | This object identifies the trap issued by the network element. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.2 | ColumnnetrapId | read-only | mandatory | The value of this objest is the trap ID number provided by network element. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.3 | ColumnnetrapNetworkElemModelNumber | read-only | mandatory | The value of this object is the model number of the network element. Combination of Model # and Serial # is used as the unique identifier of the NE. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.4 | ColumnnetrapNetworkElemSerialNum | read-only | mandatory | The value of this object is the serial number of the network element. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.5 | ColumnnetrapPerceivedSeverity | read-only | mandatory | This parameter defines five severity levels, which provide an indication of the perceived status of the managed object. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.6 | ColumnnetrapNetworkElemOperState | read-only | mandatory | The current Operational State of the Network Element which generated the trap.. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.7 | ColumnnetrapNetworkElemAlarmStatus | read-only | mandatory | The current Alarm Status of the Network Element. Alarm Status is always equal to the highest severity level of all outstanding alarms in this NE.. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.8 | ColumnnetrapNetworkElemAdminState | read-only | mandatory | The current Adminsitrative state of the network element. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.9 | ColumnnetrapNetworkElemAvailStatus | read-only | mandatory | The current Operational state of the network elment |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.10 | ColumnnetrapText | read-only | mandatory | This variable contains trap text. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.11 | ColumnnetrapLastTrapTimeStamp | read-only | mandatory | This OBJECT IDENTIFIER is used to hold time when trap was generated. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.12 | ColumnnetrapChangedObjectId | read-only | mandatory | This variable identifies the object that has generated the trap. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.13 | ColumnnetrapAdditionalInfoInteger1 | read-only | mandatory | This 32 bit integer is used to hold specific information about the trap. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.14 | ColumnnetrapAdditionalInfoInteger2 | read-only | mandatory | this 32 bit integer is used to hold specific information about the trap. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.15 | ColumnnetrapAdditionalInfoInteger3 | read-only | mandatory | This 32 bit integer is used to hold specific information about the trap. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.16 | ColumnnetrapChangedValueDisplayString | read-only | mandatory | This DisplayString is used to hold specific information about the trap |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.17 | ColumnnetrapChangedValueOID | read-only | mandatory | This OBJECT IDENTIFIER is used to hold specific information about the trap |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.18 | ColumnnetrapChangedValueIpAddress | read-only | mandatory | This OBJECT IDENTIFIER is used to hold specific information about the trap. |
| 1.3.6.1.4.1.1166.6.1.2.3.11.10.19 | ColumnnetrapChangedValueInteger | read-only | mandatory | this 32 bit integer is used to hold the data value that this object has been changed too. |