OMNI-gx2LM-MIB
211 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.4.1 | Nodegx2lmDescriptor | |||
| 1.3.6.1.4.1.1166.6.1.2.4.1 | NodetrapLMConfigChangeInteger | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain curre… | ||
| 1.3.6.1.4.1.1166.6.1.2.4.2 | Tablegx2lmAnalogTable | not-accessible | mandatory | This table contains gx2Lm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.4.2 | NodetrapLMConfigChangeDisplayString | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may … | ||
| 1.3.6.1.4.1.1166.6.1.2.4.2.1 | Rowgx2lmAnalogEntry | not-accessible | mandatory | This list contains the analog parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.1 | Columngx2lmAnalogTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.2 | ColumnlabelOffsetNomMonitor | read-only | optional | The value of this object provides the label of the Offset Monitor Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.3 | ColumnuomOffsetNomMonitor | read-only | optional | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.4 | ColumnmajorHighOffsetNomMonitor | read-only | mandatory | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.5 | ColumnmajorLowOffsetNomMonitor | read-only | mandatory | The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.6 | ColumnminorHighOffsetNomMonitor | read-only | mandatory | The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.7 | ColumnminorLowOffsetNomMonitor | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.8 | ColumncurrentValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.9 | ColumnstateFlagOffsetNomMonitor | read-only | mandatory | The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.10 | ColumnminValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.11 | ColumnmaxValueOffsetNomMonitor | read-only | mandatory | The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.12 | ColumnalarmStateOffsetNomMonitor | read-only | mandatory | The value of this object provides the curent alarm state of the Offset Monitor Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.13 | ColumnlabelOffsetNomCnt | read-only | optional | The value of this object provides the label of the Offset Control Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.14 | ColumnuomOffsetNomCnt | read-only | optional | The value of this object provides the label of the Offset Control Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.15 | ColumnmajorHighOffsetNomCnt | read-only | mandatory | The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.16 | ColumnmajorLowOffsetNomCnt | read-only | mandatory | The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.17 | ColumnminorHighOffsetNomCnt | read-only | mandatory | The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.18 | ColumnminorLowOffsetNomCnt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.19 | ColumncurrentValueOffsetNomCnt | read-write | mandatory | The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEE… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.20 | ColumnstateFlagOffsetNomCnt | read-only | mandatory | The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.21 | ColumnminValueOffsetNomCnt | read-only | mandatory | The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.22 | ColumnmaxValueOffsetNomCnt | read-only | mandatory | The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.23 | ColumnalarmStateOffsetNomCnt | read-only | mandatory | The value of this object provides the curent alarm state of the Offset Control Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.24 | ColumnlabelRelAttenSetting | read-only | optional | The value of this object provides the label of the Attenuator Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.25 | ColumnuomRelAttenSetting | read-only | optional | The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.26 | ColumnmajorHighRelAttenSetting | read-only | mandatory | The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.27 | ColumnmajorLowRelAttenSetting | read-only | mandatory | The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.28 | ColumnminorHighRelAttenSetting | read-only | mandatory | The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.29 | ColumnminorLowRelAttenSetting | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.30 | ColumncurrentValueRelAttenSetting | read-write | mandatory | The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.31 | ColumnstateFlagRelAttenSetting | read-only | mandatory | The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.32 | ColumnminValueRelAttenSetting | read-only | mandatory | The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.33 | ColumnmaxValueRelAttenSetting | read-only | mandatory | The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.34 | ColumnalarmStateRelAttenSetting | read-only | mandatory | The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.35 | ColumnlabelOptPower | read-only | optional | The value of this object provides the label of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.36 | ColumnuomOptPower | read-only | optional | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.37 | ColumnmajorHighOptPower | read-only | mandatory | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.38 | ColumnmajorLowOptPower | read-only | mandatory | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.39 | ColumnminorHighOptPower | read-only | mandatory | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.40 | ColumnminorLowOptPower | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.41 | ColumncurrentValueOptPower | read-only | mandatory | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.42 | ColumnstateFlagOptPower | read-only | mandatory | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.43 | ColumnminValueOptPower | read-only | mandatory | The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.44 | ColumnmaxValueOptPower | read-only | mandatory | The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.45 | ColumnalarmStateOptPower | read-only | mandatory | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.46 | ColumnlabelLaserBias | read-only | optional | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.47 | ColumnuomLaserBias | read-only | optional | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.48 | ColumnmajorHighLaserBias | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.49 | ColumnmajorLowLaserBias | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.50 | ColumnminorHighLaserBias | read-only | mandatory | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.51 | ColumnminorLowLaserBias | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.52 | ColumncurrentValueLaserBias | read-only | mandatory | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.53 | ColumnstateFlagLaserBias | read-only | mandatory | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.54 | ColumnminValueLaserBias | read-only | mandatory | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.55 | ColumnmaxValueLaserBias | read-only | mandatory | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.56 | ColumnalarmStateLaserBias | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.57 | ColumnlabelTecCurrent | read-only | optional | The value of this object provides the label of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.58 | ColumnuomTecCurrent | read-only | optional | The value of this object provides the Unit of Measure of the TEC Current Analog parameter.. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.59 | ColumnmajorHighTecCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.60 | ColumnmajorLowTecCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.61 | ColumnminorHighTecCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.62 | ColumnminorLowTecCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.63 | ColumncurrentValueTecCurrent | read-only | mandatory | The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.64 | ColumnstateFlagTecCurrent | read-only | mandatory | The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.65 | ColumnminValueTecCurrent | read-only | mandatory | The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.66 | ColumnmaxValueTecCurrent | read-only | mandatory | The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.67 | ColumnalarmStateTecCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.68 | ColumnlabelLaserTemp | read-only | optional | The value of this object provides the label of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.69 | ColumnuomLaserTemp | read-only | optional | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.70 | ColumnmajorHighLaserTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.71 | ColumnmajorLowLaserTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.72 | ColumnminorHighLaserTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.73 | ColumnminorLowLaserTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.74 | ColumncurrentValueLaserTemp | read-only | mandatory | The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.75 | ColumnstateFlagLaserTemp | read-only | mandatory | The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.76 | ColumnminValueLaserTemp | read-only | mandatory | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.77 | ColumnmaxValueLaserTemp | read-only | mandatory | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represente… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.78 | ColumnalarmStateLaserTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.79 | ColumnlabelModuleTemp | read-only | optional | The value of this object provides the label of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.80 | ColumnuomModuleTemp | read-only | optional | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.81 | ColumnmajorHighModuleTemp | read-only | mandatory | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.82 | ColumnmajorLowModuleTemp | read-only | mandatory | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.83 | ColumnminorHighModuleTemp | read-only | mandatory | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represen… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.84 | ColumnminorLowModuleTemp | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.85 | ColumncurrentValueModuleTemp | read-only | mandatory | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.86 | ColumnstateFlagModuleTemp | read-only | mandatory | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.87 | ColumnminValueModuleTemp | read-only | mandatory | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.88 | ColumnmaxValueModuleTemp | read-only | mandatory | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represent… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.89 | ColumnalarmStateModuleTemp | read-only | mandatory | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.90 | ColumnlabelFanCurrent | read-only | optional | The value of this object provides the label of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.91 | ColumnuomFanCurrent | read-only | optional | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.92 | ColumnmajorHighFanCurrent | read-only | mandatory | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.93 | ColumnmajorLowFanCurrent | read-only | mandatory | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.94 | ColumnminorHighFanCurrent | read-only | mandatory | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.95 | ColumnminorLowFanCurrent | read-only | mandatory | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.96 | ColumncurrentValueFanCurrent | read-only | mandatory | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.97 | ColumnstateFlagFanCurrent | read-only | mandatory | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.98 | ColumnminValueFanCurrent | read-only | mandatory | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.99 | ColumnmaxValueFanCurrent | read-only | mandatory | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.100 | ColumnalarmStateFanCurrent | read-only | mandatory | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.101 | Columnlabel12Volt | read-only | optional | The value of this object provides the label of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.102 | Columnuom12Volt | read-only | optional | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.103 | ColumnmajorHigh12Volt | read-only | mandatory | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.104 | ColumnmajorLow12Volt | read-only | mandatory | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.105 | ColumnminorHigh12Volt | read-only | mandatory | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as … |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.106 | ColumnminorLow12Volt | read-only | mandatory | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.107 | ColumncurrentValue12Volt | read-only | mandatory | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 3… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.108 | ColumnstateFlag12Volt | read-only | mandatory | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.109 | ColumnminValue12Volt | read-only | mandatory | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.110 | ColumnmaxValue12Volt | read-only | mandatory | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as a… |
| 1.3.6.1.4.1.1166.6.1.2.4.2.1.111 | ColumnalarmState12Volt | read-only | mandatory | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3 | Tablegx2lmDigitalTable | not-accessible | mandatory | This table contains gx2Lm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.4.3 | NodetrapLMRFInputAlarm | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parame… | ||
| 1.3.6.1.4.1.1166.6.1.2.4.3.2 | Rowgx2lmDigitalEntry | not-accessible | mandatory | This list contains digital parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.1 | Columngx2lmDigitalTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.2 | ColumnlabelRfInput | read-only | optional | The value of this object provides the label of the RF Input Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.3 | ColumnenumRfInput | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.4 | ColumnvalueRfInput | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.5 | ColumnstateflagRfInput | read-only | mandatory | The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.6 | ColumnlabelOptOutput | read-only | optional | The value of this object provides the label of the Optical Output Control Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.7 | ColumnenumOptOutput | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.8 | ColumnvalueOptOutput | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.9 | ColumnstateflagOptOutput | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.10 | ColumnlabelLaserMode | read-only | optional | The value of this object provides the label of the Laser Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.11 | ColumnenumLaserMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.12 | ColumnvalueLaserMode | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.13 | ColumnstateflagLaserMode | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.14 | ColumnlabelLaserSecMode | read-only | optional | The value of this object provides the label of the Laser Secondary Mode Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.15 | ColumnenumLaserSecMode | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.16 | ColumnvalueLaserSecMode | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.17 | ColumnstateflagLaserSecMode | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.18 | ColumnlabelVideoOffset | read-only | optional | The value of this object provides the label of the Video Offset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.19 | ColumnenumVideoOffset | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.20 | ColumnvalueVideoOffset | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.21 | ColumnstateflagVideoOffset | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.22 | ColumnlabelFactoryDefault | read-only | optional | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.23 | ColumnenumFactoryDefault | read-only | optional | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value… |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.24 | ColumnvalueFactoryDefault | read-write | mandatory | The value of this object is the current value of the parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.3.2.25 | ColumnstateflagFactoryDefault | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.4 | Tablegx2lmStatusTable | not-accessible | mandatory | This table contains gx2Lm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.4.4 | NodetrapLMRFOverloadAlarm | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.4.4.3 | Rowgx2lmStatusEntry | not-accessible | mandatory | This list contains Status parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.1 | Columngx2lmStatusTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.2 | ColumnlabelBoot | read-only | optional | The value of this object provides the label of the Boot Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.3 | ColumnvalueBoot | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.4 | ColumnstateflagBoot | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.5 | ColumnlabelFlash | read-only | optional | The value of this object provides the label of the Flash Status Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.6 | ColumnvalueFlash | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.7 | ColumnstateflagFlash | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.8 | ColumnlabelFactoryDataCRC | read-only | optional | The value of this object provides the label of the Factory Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.9 | ColumnvalueFactoryDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.10 | ColumnstateflagFactoryDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.11 | ColumnlabelLaserDataCRC | read-only | optional | The value of this object provides the label of the Laser Data CRC Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.12 | ColumnvalueLaserDataCRC | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.13 | ColumnstateflagLaserDataCRC | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.14 | ColumnlabelAlarmDataCrc | read-only | optional | The value of this object provides the label of the Alarm Data Crc parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.15 | ColumnvalueAlarmDataCrc | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.16 | ColumnstateflagAlarmDataCrc | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.17 | ColumnlabelHWStatus | read-only | optional | The value of this object provides the label of the Laser Drive Level Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.18 | ColumnvalueHWStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.19 | ColumnstateflagHWStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.20 | ColumnlabelRFInputStatus | read-only | optional | The value of this object provides the label of the RF Input Status parameter. |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.21 | ColumnvalueRFInputStatus | read-only | mandatory | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| 1.3.6.1.4.1.1166.6.1.2.4.4.3.22 | ColumnstateflagRFInputStatus | read-only | mandatory | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| 1.3.6.1.4.1.1166.6.1.2.4.5 | Tablegx2lmFactoryTable | not-accessible | mandatory | This table contains gx2Lm specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.4.5 | NodetrapLMRFOffsetAlarm | This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this param… | ||
| 1.3.6.1.4.1.1166.6.1.2.4.5.4 | Rowgx2lmFactoryEntry | not-accessible | mandatory | This list contains Factory parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.1 | Columngx2lmFactoryTableIndex | read-only | mandatory | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.2 | ColumnbootControlByteValue | read-only | mandatory | The value of this object indicates which bank the firmware is currently being boot from. |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.3 | ColumnbootStatusByteValue | read-only | mandatory | This object indicates the status of the last boot |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.4 | Columnbank1CRCValue | read-only | mandatory | This object provides the CRC code of bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.5 | Columnbank2CRCValue | read-only | mandatory | This object provides the CRC code of bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.6 | ColumnprgEEPROMByteValue | read-only | mandatory | This object indicates if the EEPROM has been programmed |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.7 | ColumnfactoryCRCValue | read-only | mandatory | This object provides the CRC code for the Factory data. |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.8 | ColumncalculateCRCValue | read-only | mandatory | This object indicates which of the Emnums will have the CRC calculated. |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.9 | ColumnhourMeterValue | read-only | mandatory | This object provides the hour meter reading of the module. |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.10 | ColumnflashPrgCntAValue | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.11 | ColumnflashPrgCntBValue | read-only | mandatory | This object provides the number of times Bank 1 flash has been programmed. |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.12 | ColumnflashBankARevValue | read-only | mandatory | This object provides the revision of flash bank 0. |
| 1.3.6.1.4.1.1166.6.1.2.4.5.4.13 | ColumnflashBankBRevValue | read-only | mandatory | This object provides the revision of flash bank 1. |
| 1.3.6.1.4.1.1166.6.1.2.4.6 | Tablegx2Lm1000HoldTimeTable | not-accessible | mandatory | This table contains gx2Lm1000 specific parameters with nominal and current values. |
| 1.3.6.1.4.1.1166.6.1.2.4.6 | NodetrapLMOpticalPowerAlarm | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this p… | ||
| 1.3.6.1.4.1.1166.6.1.2.4.6.5 | Rowgx2Lm1000HoldTimeEntry | not-accessible | mandatory | This list contains digital product class and the associated RF channel parameters and descriptions. |
| 1.3.6.1.4.1.1166.6.1.2.4.6.5.1 | Columngx2Lm1000HoldTimeTableIndex | read-only | mandatory | The value of this object is the index of the data object. |
| 1.3.6.1.4.1.1166.6.1.2.4.6.5.2 | Columngx2Lm1000HoldTimeSpecIndex | read-only | mandatory | The value of this object identifies the index of the alarm object to be modified. |
| 1.3.6.1.4.1.1166.6.1.2.4.6.5.3 | Columngx2Lm1000HoldTimeData | read-write | mandatory | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered… |
| 1.3.6.1.4.1.1166.6.1.2.4.7 | NodetrapLMLaserBiasAlarm | This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.8 | NodetrapLMLaserTempAlarm | This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.9 | NodetrapLMTECCurrentAlarm | This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.4.10 | NodetrapLMFanCurrentAlarm | This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this par… | ||
| 1.3.6.1.4.1.1166.6.1.2.4.11 | NodetrapLM12vAlarm | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this paramet… | ||
| 1.3.6.1.4.1.1166.6.1.2.4.12 | NodetrapLMModuleTempAlarm | This trap is issued when the Laser Module Temperature goes out of range. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.13 | NodetrapLMFlashAlarm | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.14 | NodetrapLMLaserBiasCntLoopAlarm | This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.15 | NodetrapLMBankBootAlarm | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.16 | NodetrapLMLaserBiasCntLoopInitAlarm | This trap is issued when the Laser Bias Control loop init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.17 | NodetrapLMRFParamInitAlarm | This trap is issued when the RF parameter Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.18 | NodetrapLMTECParamInitAlarm | This trap is issued when the TEC Parameter Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.19 | NodetrapLMAttnTableInitAlarm | This trap is issued when the Attenuator Table Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.20 | NodetrapLMPowerMeterTableInitAlarm | This trap is issued when the Power Meter Table Init fails. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.21 | NodetrapLMLaserDataCRCAlarm | This trap is issued when the Laser Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.22 | NodetrapLMAlarmDataCRCAlarm | This trap is issued when the Alarm Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.23 | NodetrapLMFactoryDataCRCAlarm | This trap is issued when the Factory Data CRC is incorrect. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.24 | NodetrapLMUserRFOffAlarm | This trap is issued when the the User RF is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.25 | NodetrapLMUserOpticalOffAlarm | This trap is issued when the User Optical Power is turned off. | ||
| 1.3.6.1.4.1.1166.6.1.2.4.26 | NodetrapLMResetFactoryDefaultAlarm | This trap is issued when the Factory Default Reset occurs. |